Yokogawa AMM11 Analog Input Multiplexer ModuleYokogawa AMM11 Analog Input Multiplexer ModuleYokogawa AMM11 Analog Input Multiplexer Module
Yokogawa AMM11 Analog Input Multiplexer Module
Yokogawa AMM11 Analog Input Multiplexer Module
Yokogawa AMM11 Analog Input Multiplexer Module

Yokogawa AMM11 Analog Input Multiplexer Module


Only 10 left - Selling fast

PRODUCT SKU : AMM11

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Yokogawa AMM11, also cataloged as the AMM11 Input Multiplexer Module, operates as a dedicated hardware component for high-density analog signal processing and field signal routing within Yokogawa CENTUM VP and CENTUM CS 3000 systems.

Hardware Specifications

Parameter Specification
Model AMM11
Brand Yokogawa
Origin Japan
Input Channel Density 64 isolated channels
Signal Current Range 4 mA to 20 mA DC
Signal Voltage Range -10 V to +10 V DC
Weight 0.4 kg
Dimensions Standard Yokogawa I/O Module Slot Form Factor
Operating Temp 0 to 50 deg C
Power Consumption 3.5 W

Yokogawa Channel-to-Channel Isolation & Signal Conditioning

The AMM11 module integrates 64 isolated channels designed to multiplex differential voltage and current loop signals before analog-to-digital processing. Channel-to-channel isolation prevents ground loop currents between field sensors and internal backplane logic. The module conditions 4-20 mA HART loop protocol and -10 V to +10 V inputs, filtering high-frequency noise and suppressing common-mode interference prior to routing data across the CENTUM backplane.

Frequently Asked Questions

Q: How does the AMM11 handle signal conditioning across its 64 channels simultaneously?

A: The AMM11 utilizes internal solid-state multiplexing switches combined with isolation circuitry to sequentially sample field signals while maintaining dielectric isolation between channels and system ground.

Q: What power bus draw does the AMM11 exert on the rack backplane?

A: The module draws a maximum power consumption of 3.5 W from the internal backplane supply rail during full 64-channel operation.

Field Installation Guidelines

Mount the AMM11 input multiplexer module securely into its assigned I/O slot on the CENTUM system baseplate until the locking mechanism fully engages. Wire field signal cables through compatible terminal blocks, maintaining strict separation between 4-20 mA current loops, voltage signal pairs, and high-voltage AC conductors within cabinet wire ducts. Ground signal cable shields at a single point on the enclosure earth bus bar to eliminate ground loop voltage differentials across long cable runs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more