Skip to content

What are you looking for?


You may also like

51305900-175 MC-TAIH04 Honeywell High Level Analog Input Module51305900-175 MC-TAIH04 Honeywell High Level Analog Input Module51305900-175 MC-TAIH04 Honeywell High Level Analog Input Module
51305900-175 MC-TAIH04 Honeywell High Level Analog Input Module
51305900-175 MC-TAIH04 Honeywell High Level Analog Input Module
51305900-175 MC-TAIH04 Honeywell High Level Analog Input Module

51305900-175 MC-TAIH04 Honeywell High Level Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : MC-TAIH04 51305900-175

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-accuracy signal acquisition in DCS architectures, the Honeywell 51305900-175 (MC-TAIH04 High Level Analog Input Module) provides direct physical/electrical execution for high-level analog current and voltage loop processing.

Hardware Specifications

Parameter Specification
Model 51305900-175
Brand Honeywell
Base Model MC-TAIH04
Product Type High Level Analog Input Module
Origin USA
Weight 0.8 kg
Dimensions 12.7 cm x 12.7 cm x 12.7 cm
Operating Temp 0 deg C to +60 deg C
Power Consumption System backplane powered
Signal Input Type High level analog (1-5 VDC / 4-20 mA)
Channel-to-Channel Isolation Galvanic optical isolation

Channel-to-Channel Isolation and Loop Protocol Processing

The 51305900-175 MC-TAIH04 module processes high-level process variable signals across multiple field instrument channels. Designed to interface directly with 4-20 mA HART loop protocol transmitters, the input architecture incorporates channel-to-channel isolation and galvanic decoupling to block ground potential differences between field sensor junction boxes and the central backplane. Active filtering circuits attenuate common-mode electromagnetic noise and prevent transient voltage surges from degrading analog-to-digital signal conversion precision.

Frequently Asked Questions

Q: Does the 51305900-175 module require external power supplies for field transmitter loops?

A: Loop power distribution depends on the connected field termination assembly (FTA) configuration, which routes either cabinet-supplied 24 VDC or self-powered transmitter outputs to the module inputs.

Q: Can the MC-TAIH04 input module be replaced while the system rack is powered?

A: Yes, provided the card file chassis supports active backplane extraction and the target channels are removed from active control loops prior to module disengagement.

Field Installation Guidelines

  • ESD Protection: Always wear a grounded ESD wrist strap connected to the enclosure frame before opening anti-static packaging or handling the module board.
  • Guide Rail Insertion: Align the module housing with the chassis slot guides, pushing firmly until the rear connector fully seats into the backplane receptacle.
  • Shield Continuity: Ground field instrument cable shields at the dedicated single-point cabinet instrument earth bar to prevent ground loop currents across the 4-20 mA loops.
  • Cable Separation: Maintain physical separation between incoming low-voltage analog signal wires and high-power AC distribution cabling within terminal raceways.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more