Skip to content

What are you looking for?


You may also like

ST5*A Yokogawa Multipoint Status I/O CardST5*A Yokogawa Multipoint Status I/O CardST5*A Yokogawa Multipoint Status I/O Card
ST5*A Yokogawa Multipoint Status I/O Card
ST5*A Yokogawa Multipoint Status I/O Card
ST5*A Yokogawa Multipoint Status I/O Card

ST5*A Yokogawa Multipoint Status I/O Card


Only 10 left - Selling fast

PRODUCT SKU : ST5*A

PRODUCT TYPE : Multipoint I/O Cards

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Yokogawa ST5*A, also cataloged as the ST5 Multipoint Status Input/Output Card, operates as a dedicated hardware component for multi-channel discrete status monitoring and analog signal conditioning within CENTUM system nodes.

Hardware Specifications

Parameter Specification
Model ST5*A
Brand Yokogawa
Origin Japan
Module Type Multipoint Status Input/Output Card
I/O Channels 16 Analog Inputs, 8 Digital Inputs/Outputs
Analog Input Range 4-20 mA
Supply Voltage 12-36 V DC
Communication Interface RS-485
Weight 1.36 kg
Dimensions Standard Rack Slot Module Form Factor
Operating Temp -20 to +85 deg C (-4 to +185 deg F)
Power Consumption Operating current draw on 12-36 V DC line

Loop Protocol Integration & Signal Conditioning

The ST5*A multipoint status card routes field variables through dedicated 4-20 mA HART loop protocol conversion paths and isolated digital I/O channels. Internal signal conditioning circuitry rejects common-mode line noise across the 16 analog input channels, preserving analog-to-digital resolution before passing process data over the onboard RS-485 serial communication interface.

Frequently Asked Questions

Q: What power input constraints apply to the ST5*A I/O card?

A: The card accepts an auxiliary direct current supply voltage ranging from 12 V DC to 36 V DC across its field power terminals.

Q: How are digital and analog signals physically mapped across the card terminal interface?

A: The unit divides its terminal connections into 16 discrete 4-20 mA analog input channels alongside 8 configurable digital input/output channels.

Field Installation Guidelines

Mount the ST5*A card into the assigned rack enclosure slot using the integrated guide channels until the backplane connectors fully seat. Connect incoming 4-20 mA current loop wiring and RS-485 bus lines using shielded twisted-pair cables. Ground all cable shields at a single dedicated earth ground point on the cabinet terminal strip to prevent ground loop interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more