2MLF-DV8A Honeywell MasterLogic-200 Analog Output Module
2MLF-DV8A Honeywell MasterLogic-200 Analog Output Module
2MLF-DV8A Honeywell MasterLogic-200 Analog Output Module

2MLF-DV8A Honeywell MasterLogic-200 Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : 2MLF-DV8A

PRODUCT TYPE : Analog Output Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 2MLF-DV8A, also cataloged as the 2MLF-DV8A Analog Output Module, operates as a dedicated hardware component for multi-channel voltage signal generation within MasterLogic-200 platforms.

Hardware Specifications

Parameter Specification
Model 2MLF-DV8A
Brand Honeywell
Origin South Korea
Operating Temp 0 to 55 deg C
Power Consumption Standard MasterLogic-200 backplane bus load
Output Type Voltage source
Number of Channels 8 channels
Output Signal Ranges 0 to 10 VDC, -10 to +10 VDC, 0 to 5 VDC, 1 to 5 VDC
Load Resistance 1 kohm or greater
Range Configuration Software selectable via application parameters

Channel Isolation & Signal Conditioning

The 2MLF-DV8A drives 8 independent analog voltage loops across multi-range control configurations. Channel-to-channel isolation and backplane decoupling protect digital logic from external field transient surges. Internal digital-to-analog converters (DAC) process internal PLC bus register data into stable voltage commands (0 to 10 VDC, -10 to +10 VDC, 0 to 5 VDC, or 1 to 5 VDC) with loop stability maintained when tied to field loads of 1 kohm or greater.

Frequently Asked Questions

Q: How are individual output ranges configured on the 2MLF-DV8A module?

A: Output ranges (0 to 10 VDC, -10 to +10 VDC, 0 to 5 VDC, 1 to 5 VDC) are configured per channel via software application parameters within the PLC programming environment.

Q: What is the minimum allowable load resistance for the voltage output loops?

A: Connected field devices or actuator inputs must maintain a load resistance of 1 kohm or greater to prevent output current saturation.

Q: Can the module be inserted into the rack while the backplane is powered?

A: Power to the base rack must be isolated prior to module insertion or removal to prevent physical hardware damage to backplane bus contacts.

Field Installation Guidelines

  1. Turn off all main power sources to the PLC base unit before installing or removing the 2MLF-DV8A module from the backplane rack.
  2. Ensure field signal cables connected to the voltage output terminals use shielded twisted-pair conductors to minimize electromagnetic noise coupling.
  3. Terminate individual cable shields directly to the cabinet ground bar at a single point to prevent ground loop currents across signal references.
  4. Align module base edge connectors with the backplane slot guide channels and push firmly until the top and bottom retention latches engage completely.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more