Honeywell 51304421-200 Circuit BoardHoneywell 51304421-200 Circuit BoardHoneywell 51304421-200 Circuit Board
Honeywell 51304421-200 Circuit Board
Honeywell 51304421-200 Circuit Board
Honeywell 51304421-200 Circuit Board

Honeywell 51304421-200 Circuit Board


Only 10 left - Selling fast

PRODUCT SKU : 51304421-200

PRODUCT TYPE : Relay Output Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 51304421-200, also cataloged as the 51304421 PLCG Relay Panel Card, operates as a dedicated hardware component for relay output switching and programmable logic controller gateway interface execution within Honeywell TDC 3000 systems.

Hardware Specifications

Parameter Specification
Model 51304421-200
Brand Honeywell
Origin USA
Weight Approx. 0.85 kg
Operating Temp 0 deg C to +60 deg C
Power Consumption Max. 10 W via chassis backplane supply
Module Type PLCG Relay Panel Card / Circuit Board
System Compatibility Honeywell TDC 3000 / PLCG Gateway
Signal Output Multi-channel discrete relay switching outputs
Mounting Type Chassis / Rack Mount

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The 51304421-200 relay panel card incorporates high-dielectric isolation barriers between internal logic controls and switching channels to enforce channel-to-channel isolation across all output paths. This isolation prevents field inductive kickback, voltage surges, and common-mode transients from corrupting adjacent system buses or interfering with analog loops processing 4-20 mA HART loop protocol telemetry in shared process control enclosures.

Frequently Asked Questions

Q: What is the primary function of the 51304421-200 in a TDC 3000 architecture?

A: The board provides relay output switching control and signal interfacing between the Programmable Logic Controller Gateway (PLCG) and connected field devices or intermediate terminal assemblies.

Q: Can the 51304421-200 board be hot-swapped while the rack backplane is powered?

A: No, backplane power to the PLCG rack section must be de-energized or field outputs bypassed prior to removing or inserting the card to prevent voltage arcs and logic reset faults.

Q: How is field cabling interfaced to the 51304421-200 circuit board?

A: Cabling connects via dedicated multi-pin edge headers or interface ribbon harnesses linked to adjacent field termination assemblies.

Field Installation Guidelines

  • Ensure backplane supply power is isolated and locked out before seating the circuit card into the rack slot.
  • Observe static discharge protocols and wear an ESD grounding wrist strap during physical handling.
  • Verify male edge-connector contacts are clean and free of oxidation before inserting the board into the card cage.
  • Fasten front-panel retaining screws securely to ensure proper mechanical ground continuity with the cabinet chassis.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

In industrial automation, connecting physical hardware with high-level software remains a primary operational challenge. Factories utilize programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and smart sensors from diverse vendors. These devices often speak different proprietary protocols. Open Platform Communications (OPC) servers solve this interoperability challenge by standardizing how data flows across factory networks.

Read more
Industrial Fiber Optic Cables: Principles, Connectors, and Fusion Splicing Techniques

Industrial Fiber Optic Cables: Principles, Connectors, and Fusion Splicing Techniques

Modern factory automation relies heavily on fiber optic cables for high-speed industrial data transmission. Fiber optic cables transmit light pulses instead of electrical signals, eliminating electromagnetic interference (EMI) risks completely. Each optical strand consists of a high-purity glass core surrounded by a protective cladding layer. The difference in refractive index between core and cladding enables total internal reflection. Protective resin buffers, Kevlar strength members, and rugged outer jackets safeguard delicate glass cores in harsh environments. Consequently, automation engineers prefer fiber backbones for reliable noise-free communication in industrial control systems.

Read more
Comprehensive Guide to Instrumentation and Control (I&C) Design Basis

Comprehensive Guide to Instrumentation and Control (I&C) Design Basis

Instrumentation and Control (I&C) Design Basis serves as the foundational technical document for modern plant engineering. Project teams rely on this master specification to govern engineering deliverables across front-end engineering design (FEED) and detailed execution phases. A well-constructed I&C design basis ensures seamless integration among field instrumentation, safety systems, and main control systems. Furthermore, establishing clear technical standards early mitigates execution risks and prevents costly re-engineering during plant commissioning.

Read more