PRODUCT SKU : 51304920-100

PRODUCT TYPE : Serial Interface Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for data exchange within TDC 3000 Distributed Control System architectures, the Honeywell 51304920-100 (51304920-100 Serial Interface Module) provides direct physical and electrical execution of serial communication between controllers and field instruments.

Hardware Specifications

Parameter Specification
Model 51304920-100
Brand Honeywell
Origin USA
Weight 0.5 kg
Dimensions 216 x 160 x 30 mm
Communication Ports RS-232, RS-485
System Compatibility TDC 3000 DCS

DCS Process Control and Connectivity

The 51304920-100 module manages serial data traffic by supporting both RS-232 and RS-485 physical layer standards. Within the DCS environment, this interface card maintains channel-to-channel isolation on the serial bus, which prevents ground potential differences between remote field devices and the controller backplane from inducing data errors. By providing robust signal buffering, the module mitigates electromagnetic interference (EMI) typical in industrial cabling runs. Additionally, the assembly facilitates integration with 4-20 mA HART loop protocol instruments when used in conjunction with appropriate signal converters, ensuring that serial diagnostic data is successfully merged with primary process control loops.

Frequently Asked Questions

Q: Does this module support hot-swapping on a live rack?

A: The 51304920-100 is not designed for hot-swapping. Inserting or removing the module while the backplane is powered can induce transient voltages that may damage the serial communication buffers or interrupt the processor bus communication.

Q: Are there specific termination requirements for the RS-485 port?

A: Yes. When utilizing the RS-485 port in multi-drop configurations, ensure that 120 Ohm termination resistors are installed at both physical ends of the communication line to prevent signal reflections and data collisions.

Field Installation Guidelines

  1. Ensure the control rack is de-energized and all power sources are isolated before module installation.
  2. Carefully slide the module into the designated rack slot, ensuring the edge connector is fully engaged with the backplane socket.
  3. Secure the module front panel to the rack frame using the provided mounting hardware to guarantee chassis grounding and structural stability.
  4. Route RS-232/RS-485 cabling through shielded conduits, keeping signal lines physically separated from high-voltage AC power lines to minimize noise induction.
  5. Verify cable integrity and termination resistance before establishing communication with field instruments.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more