Skip to content

What are you looking for?


You may also like

Honeywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDCHoneywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDCHoneywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDC
Honeywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDC
Honeywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDC
Honeywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDC

Honeywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDC


Only 10 left - Selling fast

PRODUCT SKU : TC-ODJ161

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The TC-ODJ161 is a high-capacity discrete output module designed for the Honeywell Experion PKS and PlantScape controller platforms. This module provides 16 isolated output points, allowing for the independent switching of 24VDC field loads. Engineered for high-demand industrial environments, it features robust electrical isolation to protect the internal controller backplane from field-side voltage spikes and electrical noise, ensuring consistent uptime in mission-critical applications.

Technical Specifications

  • Model Designation: TC-ODJ161

  • Output Type: Isolated Discrete Digital Output

  • Channel Density: 16 Points

  • Operating Voltage: 24 VDC (Nominal)

  • Current Rating (Individual): Up to 2.0 Amps per channel

  • Total Module Capacity: 8.0 Amps maximum total load

  • Mounting Interface: Standard I/O Rack/Chassis slot

  • Net Weight: 0.20 kg (approx. 0.44 lbs)

  • Lifecycle Status: Discontinued by Manufacturer (Legacy Support available)

Implementation and Load Management

The TC-ODJ161 is frequently utilized for driving high-current field devices such as solenoid valves, motor starters, and large relays. While individual channels can handle peak currents up to 2.0 Amps, system designers must ensure that the simultaneous activation of multiple outputs does not exceed the aggregate 8.0 Amp module limit. Proper heat dissipation within the enclosure is recommended when operating at high current densities.

Frequently Asked Questions

  • What is the benefit of the isolated channel design?

    Isolation ensures that a fault or short circuit on one field device does not propagate to other channels or damage the sensitive electronics of the PLC backplane.

  • Can this module drive AC loads?

    No, the TC-ODJ161 is specifically designed for DC current switching. For AC applications, a dedicated relay or Triac output module should be used.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more