The ABB IIMKM02A is a ruggedized industrial input device engineered for the Bailey Infi 90 and Network 90 Distributed Control Systems (DCS). Operating via the Multibus communication protocol, this keyboard serves as a primary interface for operator consoles, enabling real-time process adjustments, alarm management, and system navigation. Its heavy-duty construction is designed to withstand the continuous demands of 24/7 control room environments, ensuring tactile reliability and low-latency response during critical industrial operations.

Specifications

  • Brand: ABB Bailey

  • Model Number: IIMKM02A

  • Product Type: Multibus Keyboard Module

  • Series: Infi 90 / Network 90

  • Communication Interface: Multibus

  • Design: Sealed industrial tactile interface

  • Net Weight: 1.85 kg (4.08 lbs)

  • Target Application: Operator Interface Stations (OIS)

Features

  • Deterministic Input: Optimized for Multibus architectures to provide immediate feedback for operator commands.

  • Control-Specific Layout: Features dedicated function keys for industrial tasks, including alarm silencing and point selection.

  • Environmental Resistance: Built to resist dust and debris common in industrial control room settings.

  • Seamless DCS Integration: Plugs directly into compatible Infi 90 consoles without the need for external drivers.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more