Technical Overview

The F60 DIO 24/16 01 is a high-density safety-related I/O component engineered for the HIMatrix F60 system. This module provides a robust interface for 24 digital inputs and 16 digital outputs within a compact 4HP form factor, specifically designed for applications requiring up to SIL 3 safety integrity. Its architecture features comprehensive galvanic isolation to maintain signal purity and protect the central processing unit from field-side electrical interference.

Detailed Specifications

  • Model Number: F60 DIO 24/16 01

  • Part Number: 984420102

  • Module Type: Integrated Digital Input/Output (24 IN / 16 OUT)

  • Operating Voltage Range: 24 VDC (-15% to +20%)

  • Internal Current Consumption: 380 mA at 24 VDC / 150 mA at 3.3 VDC

  • Input Configuration: 24 Channels, Galvanically Isolated

  • High Level Logic Threshold: 10 VDC to 30 VDC (Nominal 24 VDC)

  • Low Level Logic Threshold: 0 VDC to 5 VDC

  • Input Current Draw: 2 mA at 10V up to 5 mA at 24V

  • Switching Point Sensitivity: Typical 7.5 V

  • Output Configuration: 16 Channels, Galvanically Isolated

  • Output Voltage Delivery: 18.4 VDC to 26.8 VDC

  • Internal Voltage Drop: Maximum 2V at 2A load

  • Sensor Supply Capacity: 3 channels providing 20 V / 100 mA each (Short-circuit protected)

  • Form Factor: 6 RU height, 4 HP width

  • Unit Weight: 260 g

  • Thermal Limits: 0°C to +60°C operating / -40°C to +85°C storage

Application and Diagnostics

The F60 DIO 24/16 01 is frequently deployed in emergency shutdown (ESD) systems and fire and gas (F&G) logic solvers. It utilizes internal self-testing routines to ensure fault detection in real-time. The integrated sensor power outputs simplify the wiring of field devices such as dry contacts or proximity switches by providing supervised 20V power directly from the module.

Technical FAQ

How does the module handle output short circuits?The F60 DIO 24/16 01 includes built-in protection mechanisms that monitor current levels and will shut down the affected channel to prevent hardware damage, resuming operation once the fault is cleared.

Is this module compatible with all HIMatrix F60 chassis?Yes, it is designed for standard F60 racks and communicates via the system backplane to ensure high-speed safety data exchange.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering PLC Programming: Best Practices for Robust Industrial Automation

Mastering PLC Programming: Best Practices for Robust Industrial Automation

Writing clean PLC code requires discipline, especially regarding memory management. Avoid overusing SET and RESET instructions, as they often complicate debugging. If multiple rungs control the same bit, troubleshooting becomes a nightmare. Instead, focus on energizing a bit in only one location. If your logic requires complex conditions, use branches within a single rung. This approach keeps your code readable, maintainable, and significantly easier to audit during downtime.

Read more
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more