Configured for hardware integration in control networks, the Woodward 8923-1262 (8923-1262 Installation Kit) provides direct electrical execution of communication interface expansion for easYgen-3x00 and RP3000 series platforms.

Hardware Specifications

Parameter Specification
Model 8923-1262
Brand Woodward
Origin Not specified
Weight 0.2 kg
Operating Temp -40 deg C to +70 deg C
Operating Voltage 24 VDC
Communication Protocols Modbus RTU, Ethernet/IP

Actuator Loop Feedback Response and Thermal Heat Sink Dissipation Profiles

The 8923-1262 kit facilitates the expansion of communication interfaces for localized control systems. The assembly is designed to maintain signal integrity for Modbus RTU and Ethernet/IP protocols, ensuring deterministic data exchange between the controller and auxiliary devices. Within the control cabinet environment, the thermal heat sink dissipation profiles of the included components are optimized for operation within the -40 to +70 deg C range. The kit minimizes impedance mismatches in communication lines, thereby supporting stable actuator loop feedback response when integrated into larger prime mover management networks.

Frequently Asked Questions

Q: Does this installation kit require external power configuration beyond the 24 VDC supply?

A: The kit operates on a 24 VDC input. Ensure that the supply is regulated and filtered to prevent common-mode noise from affecting the communication protocol latencies on the Ethernet/IP or Modbus RTU links.

Q: Is the kit compatible with redundant communication architectures?

A: The kit supports standard Modbus RTU and Ethernet/IP connectivity. Integration into redundant architectures depends on the primary controller's native port configuration and the specific network topology employed.

Field Installation Guidelines

  • Mounting: Ensure all kit components are secured to the chassis using the provided mounting hardware. Verify that the assembly does not obstruct natural airflow within the cabinet.
  • Wiring: Utilize shielded cabling for all communication connections to maintain protocol integrity. Terminate shields according to the specific ground reference requirements of the controller backplane.
  • Voltage Verification: Confirm the 24 VDC power source is stable before engaging the connection to the control series (easYgen-3x00 or RP3000).
  • Protocol Setup: After physical integration, configure the communication baud rate and network addressing within the controller software to match the specific Modbus or Ethernet/IP network parameters.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more