Configured for contact signal acquisition and relay control in Mark VIe distributed control platforms, the GE IS200TDBTH6A (IS200TDBTH6A Discrete Input/Output Terminal Board) provides direct physical/electrical execution of TMR-based discrete I/O interfacing.

Hardware Specifications

Parameter Specification
Model IS200TDBTH6A
Brand General Electric
Origin USA
Weight Not specified
Dimensions 17.8 cm x 33.02 cm
Operating Temp -30 deg C to +65 deg C
Power Consumption +5 V DC
Channel Count 24 inputs, 12 relay outputs
Input Voltage 24 V DC (nominal)

Profinet / EtherNet/IP Deterministic Networks

The IS200TDBTH6A utilizes a triple modular redundancy (TMR) architecture to maintain deterministic signal integrity across the Mark VIe I/O network. The board interfaces with three PDIO I/O packs via D-type connectors, supporting high-speed Ethernet communication with rack controllers. Its backplane bus communication velocity is optimized for sub-millisecond contact status updates, ensuring synchronized data exchange across the R, S, and T control processors. The hardware-integrated input filters provide a 12 V RMS AC voltage rejection threshold, ensuring robust noise suppression for high-density contact input arrays in electrically noisy environments.

Frequently Asked Questions

Q: Can the IS200TDBTH6A operate with a single PDIO I/O pack?

A: No. Proper operation of the TDBT terminal board requires a full set of three PDIO I/O packs to support its TMR functionality and provide adequate network redundancy. Use of a single pack will result in communication errors and incomplete I/O mapping.

Q: Is the wetting voltage adjustable on the board?

A: The board accepts an external wetting voltage source of 24, 48, or 125 V DC to supply the 24 group-isolated contact inputs. The specific voltage level must be selected based on the external field device requirements and wired to the appropriate terminal blocks.

Field Installation Guidelines

  1. Mounting: The board supports either flat mounting or DIN-rail installation. Ensure the structural integrity of the mounting surface to prevent vibration-induced stress on the surface-mount components.
  2. Network Cabling: Connect the PDIO I/O packs to the designated JR1, JS1, and JT1 connectors. Use shielded, industrial-grade Ethernet cables and ensure the cable runs are physically separated from high-voltage AC power lines to maintain signal purity.
  3. Grounding: Establish a robust connection between the board’s grounding terminals and the cabinet’s common ground plane. This is required to maintain the effectiveness of the onboard noise suppression and surge protection circuitry.
  4. Wetting Voltage Termination: Verify the voltage rating of the external wetting source before termination. Apply the source to the appropriate input groups, ensuring correct polarity to avoid damage to the input isolation barriers.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more
Optimizing Power Supply Sizing for Industrial Automation Systems

Optimizing Power Supply Sizing for Industrial Automation Systems

The power supply is the silent heartbeat of any industrial automation system. While engineers often prioritize processors and communication protocols, a stable power architecture remains the most critical factor for long-term reliability. In my 15 years of experience, I have found that neglecting power supply sizing often leads to ghost errors, intermittent field device failures, and costly production downtime.

Read more