The GE IS200SRTDH2ACB, also cataloged as the IS200SRTDH2ACB RTD Input Terminal Board, operates as a dedicated hardware component for temperature sensor signal acquisition and conditioning within Mark VIe control platforms.

Hardware Specifications

Parameter Specification
Model IS200SRTDH2ACB
Brand General Electric
Origin USA
Weight 0.6 kg
Dimensions 16.7 cm x 14.8 cm x 5.5 cm
Operating Temp Industrial rated range
Power Consumption System-bus dependent
Product Type RTD Input Terminal Board
Technology Printed circuit board

Profinet / EtherNet/IP Deterministic Networks

The IS200SRTDH2ACB module manages backplane bus communication velocity by facilitating the conversion of resistance temperature detector (RTD) analog inputs into digital signals for processing by the I/O pack. The board maintains deterministic signal integrity, ensuring that temperature data remains synchronized with the controller's scan cycle. Firmware flash compatibility is governed by the associated I/O pack, which monitors the terminal board's status and ensures the validity of sensor readings. I/O density scaling is supported through standard terminal block arrangements, providing a localized interface for multiple RTD channels while isolating sensitive signal paths from high-power electromagnetic interference within the control cabinet.

Frequently Asked Questions

Q: Is the IS200SRTDH2ACB board hot-swappable during system operation?

A: No. Replacement requires the associated I/O pack to be de-energized to prevent current spikes or potential damage to the RTD input circuitry during the removal or installation process.

Q: How is signal shielding handled on the IS200SRTDH2ACB?

A: The board provides dedicated terminals for sensor shield termination. Shields must be connected to the cabinet ground bus at the terminal board to minimize noise pickup and maintain measurement accuracy.

Field Installation Guidelines

  1. Mounting: Install the board in a clean, dry location within the control cabinet. Ensure the mounting surfaces are free of debris to prevent mechanical stress on the printed circuit board.
  2. Wiring: Terminate RTD leads to the terminal blocks according to the system wiring diagram. Ensure that 3-wire RTD configurations are correctly mapped to provide lead-resistance compensation.
  3. Grounding: Bond the board chassis to the cabinet ground using the designated earthing points. Verify that the shield termination strip has a low-impedance path to the system ground.
  4. Environment: Verify that ambient temperatures remain within specified industrial operating limits. Prevent exposure to condensation or corrosive environments that could degrade signal terminal contacts.
  5. Verification: Prior to system integration, use a calibrated resistor simulator to verify the input channel accuracy for each RTD point, confirming that the digital value reported by the controller matches the input resistance.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more
Optimizing Power Supply Sizing for Industrial Automation Systems

Optimizing Power Supply Sizing for Industrial Automation Systems

The power supply is the silent heartbeat of any industrial automation system. While engineers often prioritize processors and communication protocols, a stable power architecture remains the most critical factor for long-term reliability. In my 15 years of experience, I have found that neglecting power supply sizing often leads to ghost errors, intermittent field device failures, and costly production downtime.

Read more