PRODUCT SKU : DS200PCCAG9ACB

PRODUCT TYPE : Power Connect Card

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The DS200PCCAG9ACB functions as the primary Power Connect Card for GE's Mark V series drive systems. It provides the critical hardware interface between the control drive and the SCR (Silicon Controlled Rectifier) power bridge. This board manages the transmission of power and control signals necessary for precise motor regulation. We supply this unit as 100% Brand New, ensuring your high-voltage power assemblies operate with original manufacturer safety and efficiency.

Technical Specifications

The DS200PCCAG9ACB is engineered for high-demand regenerative drive applications:

Parameter Specification
Manufacturer GE General Electric
Series Mark V Speedtronic
Part Number DS200PCCAG9ACB
Scaling Group G9 (Regenerative)
Armature Voltage Range 240 V DC to 630 V DC
Instruction Manual GEI-100161
Hardware Revision ACB
Physical Weight 9 ounces

Engineering Advantages

  • Regenerative Energy Handling: As part of the G9 Scaling Group, this card supports regenerative drive configurations, allowing the system to feed energy back into the power source during motor braking or deceleration.

  • High-Voltage Interface Stability: The board manages armature voltages up to 630 Volts, utilizing reinforced circuit pathways to prevent arcing and electrical noise interference in the control logic.

  • Direct SCR Bridge Integration: Integrated connectors facilitate a direct link to the SCR power bridge, ensuring that firing pulses and feedback signals move with zero latency.

  • Streamlined Signal Routing: The board layout organizes power and control signals into distinct sections, simplifying cable management within the drive cabinet and reducing the risk of cross-talk.

Installation & Safety Protocols

The DS200PCCAG9ACB operates in high-voltage environments. Engineering teams must adhere to the following procedures:

  1. Lethal Voltage Mitigation: Mark V assemblies contain potentially lethal surface voltages. You must verify that all power sources are locked out and discharged before attempting to service the board.

  2. Cable Mapping: During replacement, technicians must carefully map and label every cable. Reconnecting a cable to the wrong port on the power connect card can result in catastrophic equipment failure or injury.

  3. Revision Consistency: The ACB revision includes specific hardware updates. Ensure your drive's firmware and secondary boards remain compatible with this functional level to maintain system synchronization.

FAQs

  • What is the significance of the G9 scaling group? 

  • The G9 designation indicates that this board is calibrated for regenerative drive systems. It specifically manages the bi-directional power flow required when a motor acts as a generator during deceleration.

  • Can this board handle armature voltages below 240V? 

  • GE specifies an operating range of 240–630 Volts for the DS200PCCAG9ACB. Operating outside these parameters may lead to insufficient signal strength or inaccurate feedback to the SCR bridge.

  • How do I ensure safety during the board swap? 

  • Follow the GEI-100161 manual strictly. Beyond standard LOTO (Lockout/Tagout) procedures, wait for the drive capacitors to discharge fully, as the power connect card links directly to high-voltage components.

  • Does this product ship with the required cables? 

  • This listing is for the 100% Brand New PCB only. You must reuse your existing Mark V wiring harness or order replacement cables separately if they show signs of thermal wear or insulation damage.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more