Overview

The IC200MDD842 by GE Fanuc Emerson is a discrete mixed I/O module in the VersaMax Micro PLC family, engineered for compact automation applications. It provides 32 I/O points with balanced input and output capabilities, supporting both positive and negative logic.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: VersaMax

  • Product Type: Discrete Mixed I/O Module

  • Part Number: IC200MDD842

  • Weight: 0.31 lbs (0.14 kg)

  • Bulletin: IC200

  • Total I/O Points: 32

  • Digital Inputs: 16 (Positive/Negative logic)

  • Digital Outputs: 16 (Relay or transistor type)

  • Nominal Voltage: 24 V DC

  • Load Current: 0.5 A at 30 V DC

  • LED Indicators: Yes, for each I/O point

  • Required Upgrade Version: IC200MDD842B

Features

  • Supports mixed I/O configuration for flexible control applications

  • LED status indicators for visual monitoring of each channel

  • Compatible with all VersaMax Micro PLCs for straightforward integration

  • Compact form factor saves panel space

Application Scenarios

  • Small to medium automation systems requiring combined input/output points

  • Machines with both sensing and actuator control needs

  • Panel-mounted PLC solutions in industrial control systems

FAQ

Q: How many total I/O points does IC200MDD842 provide?
A: 32 points (16 inputs and 16 outputs).

Q: What logic types are supported for inputs?
A: Positive and negative logic.

Q: Is visual status feedback available?
A: Yes, each I/O point has LED indicators.

Q: What is the maximum load current per output?
A: 0.5 A at 30 V DC.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more