Product Description

The GE Fanuc VersaMax IC200ALG432 is a mixed analog input/output module designed for compact automation systems requiring both signal acquisition and output generation. It integrates four single-ended analog input channels and two single-ended analog output channels, making it a versatile choice for monitoring and control applications. With high resolution, fast update rates, and robust filtering, this module ensures precise and stable analog signal processing.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Model / Part Number: IC200ALG432

  • Product Line: VersaMax

  • Product Type: Mixed Analog I/O Module

  • Input Channels: 4 single-ended analog inputs

  • Output Channels: 2 single-ended analog outputs

  • Input Voltage Range: ±10 VDC

  • Output Voltage Range: -10.24 VDC to +10.24 VDC

  • Resolution: 12-bit

  • Update Rate: 0.4 ms

  • Input Filter Response: 5 ms

  • Power Supply for Outputs: External 24 VDC

  • Power Consumption: 160 mA total (including load current)

  • Common Mode Voltage: 0 V

  • LED Indicators: Field power and backplane power status

  • Operating Temperature: -40°C to +70°C

  • Dimensions: Approx. 100 mm × 80 mm × 20 mm

Application Scenarios

The IC200ALG432 is ideal for automation systems requiring both analog monitoring and control. It is commonly used in process control, instrumentation, and machine automation where compact mixed I/O capability is needed.

FAQ

Q: How many analog channels are available?  A: The module provides 4 analog inputs and 2 analog outputs.

Q: What resolution does the module support?  A: It offers 12-bit resolution for precise signal processing.

Q: What power supply is required for outputs?  A: An external 24 VDC supply is required for output operation.

Comparison with Similar Models

  • IC200ALG230: Voltage input-only module, suitable for applications requiring voltage measurement.

  • IC200ALG264: Analog input module with higher channel density. The IC200ALG432 provides a balanced solution with both input and output capability in a compact design.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more