Product Details

Overview

The IC695ALG704 from GE Fanuc is a high-performance, non-isolated analog output module designed for RX3i PACSystems. It provides four configurable channels for voltage and current output, offering precise signal control for industrial automation applications.

Technical Specifications

  • Model: IC695ALG704

  • Module Type: Non-Isolated Analog Output

  • Number of Channels: 4 channels

  • Output Voltage: ±10 V DC, 0–10 V DC

  • Output Current: 0–20 mA, 4–20 mA

  • Resolution: ±10 V: 15.9 bits, 0–10 V: 14.9 bits, 0–20 mA: 15.9 bits, 4–20 mA: 15.6 bits

  • Output Load Capacity: 850 Ω maximum

  • Analog Update Rate: 8 ms per channel

  • Output Settling Time: 2 ms (0–95%)

  • Calibrated Accuracy: 0.15% full scale at 25°C, 0.30% at 60°C

  • Power Requirements:

    • 375 mA @ 3.3 V DC

    • 160 mA @ 24 V DC

  • External Power Supply: 19.2–30 V DC (nominal 24 V)

  • Output Protection: Voltage withstand –30 V for 60 s, +30 V for 1 h

  • Data Format: Floating point IEEE 32-bit or 16-bit integer in 32-bit field

  • Compatible CPUs: RX3i CPU version 3.0 or later

  • Module Weight: 0.23 kg

Applications

  • Drives analog actuators or instrumentation in RX3i PACSystems

  • Suitable for process control, machine automation, or laboratory environments

  • Provides accurate multi-channel analog outputs for voltage and current-based systems

FAQ

  • Q: Can the IC695ALG704 handle both voltage and current outputs?
    A: Yes, it supports ±10 V, 0–10 V, 0–20 mA, and 4–20 mA output signals.

  • Q: Is this module isolated?
    A: No, it is a non-isolated analog output module.

  • Q: What is the update speed for all channels?
    A: Approximately 8 milliseconds for each channel.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more