Skip to content

What are you looking for?


You may also like

KL3104X1-BA1 | Emerson | DeltaV Process Controller ModuleKL3104X1-BA1 | Emerson | DeltaV Process Controller ModuleKL3104X1-BA1 | Emerson | DeltaV Process Controller Module
KL3104X1-BA1 | Emerson | DeltaV Process Controller Module
KL3104X1-BA1 | Emerson | DeltaV Process Controller Module
KL3104X1-BA1 | Emerson | DeltaV Process Controller Module

KL3104X1-BA1 | Emerson | DeltaV Process Controller Module


Only 10 left - Selling fast

PRODUCT SKU : KL3104X1-BA1

PRODUCT TYPE : Digital I/O Card

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-density discrete output signal processing in DeltaV electronic marshalling subsystems, the Emerson KL3104X1-BA1 (KL3104X1-BA1 Intrinsically Safe Digital Output Module) provides direct physical/electrical execution. This hardware component switches low-energy field infrastructure located within hazardous environments, regulating electrical load actuation circuits while maintaining absolute isolation constraints across the local distributed backplane bus.

Hardware Specifications

Parameter Specification
Model KL3104X1-BA1
Brand Emerson
Origin U.S.A.
Weight 0.08 kg
Dimensions Standard CHARM module footprint slot width
Operating Temp -40 deg C to +70 deg C
Power Consumption +6.3 VDC at 0 mA (CHARM Bus), +24 VDC at 78 mA (Field Circuit)
Output Allocation 45 mA maximum load control loop
Shock Resistance 10g 1/2 sine wave for 11 ms
Vibration Resistance 1 mm peak-to-peak from 2 to 13.2 Hz; 0.7g from 13.2 to 150 Hz
Airborne Contaminants ISA-S71.04-1985 Class G3 compliance
Relative Humidity 5% to 95% non-condensing
Terminal Block Key Position 3E

Channel-To-Channel Isolation and Loop Performance

Mechanical execution of this terminal-mounted CHARM module relies on dedicated galvanic separation layers to ensure process loop signal integrity. The hardware architecture incorporates absolute channel-to-channel isolation parameters, checking that ground faults or transient surges on an active discrete field loop cannot propagate to neighboring hardware modules. Internal logic components utilize this electrical boundary to isolate the master controller communication framework from field circuit fluctuations, enabling reliable execution of discrete trip signals and valve actuation steps under continuous power.

Frequently Asked Questions

Q: Does this intrinsically safe output module support hot-swap exchange under live system power?

A: Yes. The hardware is designed for insertion and extraction on an energized terminal baseplate. Internal current-limiting components prevent the generation of backplane bus disturbances or communication drops across adjoining active CHARM tracks during replacement.

Q: What is the mechanical function of the 3E terminal block key assignment?

A: The 3E key position mechanically prevents an incorrect characterization module type from being inserted into a slot wired for this specific output loop configuration, reducing the risk of overvoltage hazards or hardware damage to field assets.

Field Installation Guidelines

  • Baseplate Slot Insertion: Align the rear terminal guides of the CHARM module perpendicularly with the designated baseplate receptor. Press downward until the dual mechanical retention latches click into place to prevent erratic terminal contact.

  • Intrinsically Safe Wiring Separation: All hazardous-area output loop wiring must be routed through segregated blue wiring ducts. Maintain a minimum distance of 50 mm between intrinsically safe control lines and standard non-intrinsically safe power infrastructure.

  • Shield Grounding Strategy: Terminate the cable shields at the carrier grounding bar assembly only. A single-point grounding layout must be verified at the marshalling cabinet to eliminate ground-loop induced currents on the process variable tracking lines.

  • Environmental Enclosure Parameters: For locations with Class G3 airborne contaminant profiles, the marshalling enclosure must maintain a positive-pressure air flow and keep relative humidity below the 95% threshold to eliminate condensation on active terminal contacts.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more