Skip to content

What are you looking for?


You may also like

Emerson EPRO A6740/12 Output Relay ModuleEmerson EPRO A6740/12 Output Relay ModuleEmerson EPRO A6740/12 Output Relay Module
Emerson EPRO A6740/12 Output Relay Module
Emerson EPRO A6740/12 Output Relay Module
Emerson EPRO A6740/12 Output Relay Module

Emerson EPRO A6740/12 Output Relay Module


Only 10 left - Selling fast

PRODUCT SKU : A6740/12

PRODUCT TYPE : Output Relay Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for relay contact switching and interlock execution in machinery protection systems, the Emerson EPRO A6740/12 (A6740/12 Output Relay Module) provides direct physical/electrical execution. It converts system logic commands into discrete contact state outputs across MMS6000 platforms.

Hardware Specifications

Parameter Specification
Model A6740/12
Brand Emerson EPRO
Base Model A6740/12
Origin Germany
Weight 320 g net (450 g packaged)
Dimensions 160 mm L x 60 mm W x 128.4 mm H
Operating Temp 0 to 65 deg C (32 to 149 deg F)
Power Consumption Rack backplane powered
Output Type 16-Channel Relay
Mounting Format DIN 41494 Eurocard (3HE/12TE)
Storage Temp -40 to 70 deg C
Humidity Tolerance 5% to 95% non-condensing
Vibration Proof 0.15 mm at 10-55 Hz, 19.6 m/s2 at 55-150 Hz (IEC 68-2-6)
Shock Resistance 98 m/s2 for 16 ms pulses (IEC 68-2-29)

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The A6740/12 relay module features 16 discrete relay channels engineered with channel-to-channel isolation to prevent electrical interference between external switching circuits. This galvanic separation ensures that contact closures or field ground faults do not couple into adjacent control loops or 4-20 mA HART DCS instrumentation interfaces connected within the main machinery monitoring system.

Frequently Asked Questions

Q: What mounting standards and rack formats are compatible with the A6740/12 module?

A: The module conforms to the DIN 41494 Eurocard standard in a 3HE/12TE form factor, fitting standard Eurocard chassis and Emerson EPRO MMS6000 systems.

Q: What environmental shock and vibration resistance limits apply to the module?

A: The module complies with IEC 68-2-6 for vibration (0.15 mm at 10-55 Hz, 19.6 m/s2 at 55-150 Hz) and IEC 68-2-29 for shock resistance (98 m/s2 for 16 ms pulses).

Q: What wiring termination method is used for field contact connections?

A: Field connections utilize spring-clip terminal connectors to maintain wire contact retention under vibration without requiring screwed terminal maintenance.

Field Installation Guidelines

  1. Power down the designated rack slot before inserting the Eurocard module into the MMS6000 chassis.
  2. Align the module card edges with the 3HE/12TE rack guide slots and push firmly until rear connectors engage the backplane.
  3. Fasten the front panel retention screws to secure the unit against mechanical vibration and ensure frame grounding.
  4. Connect field output conductors using the spring-clip terminal connectors, verifying stripping lengths to prevent exposed leads.
  5. Ensure field relay contact load voltages and currents do not exceed maximum specified ratings before energizing loop power.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Instrumentation Control Systems in Modern Industrial Automation

Understanding Instrumentation Control Systems in Modern Industrial Automation

An instrumentation control system (ICS) serves as the central nervous system of modern manufacturing plants and processing facilities. Engineers classify these setups as Electrical, Electronic, or Programmable Electronic Systems (E/E/PES). In practice, an ICS bridges the physical world of industrial machinery with digital decision-making tools. Therefore, understanding its architecture is essential for anyone working in factory automation, process control, or plant safety.

Read more
Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Electrical grounding is a complex engineering discipline. It requires deep knowledge of soil composition and conductor materials. National Electrical Code (NEC) Article 250 outlines these requirements clearly. Many engineers confuse grounding, earthing, and bonding. Grounding connects circuits to a common reference point. Earthing specifically links equipment directly to the planet. Bonding permanently joins metallic parts to ensure electrical continuity.

Read more
Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

According to IEC 62443, Industrial Automation and Control Systems (IACS) integrate personnel, hardware, and software. These components collectively influence the safety and reliability of any industrial process. Modern control systems allow extensive remote monitoring and operation. However, enabling remote capabilities introduces complex cybersecurity challenges. Therefore, facility operators must evaluate system functions carefully before expanding connectivity.

Read more