Emerson DeltaV KJ3002X1-BB1 8-Channel 4–20mA Analog Output Module
Emerson DeltaV KJ3002X1-BB1 8-Channel 4–20mA Analog Output Module
Emerson DeltaV KJ3002X1-BB1 8-Channel 4–20mA Analog Output Module

Emerson DeltaV KJ3002X1-BB1 8-Channel 4–20mA Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : KJ3002X1-BB1

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Emerson DeltaV Analog Output Module, model KJ3002X1-BB1, is an 8-channel unit designed to deliver precise 4–20mA current loop control for distributed automation systems. Built for reliability and accuracy, this module provides stable signal conversion and seamless integration into DeltaV architectures. Its compact design, galvanic isolation, and robust environmental ratings make it suitable for demanding industrial applications.

Technical Specifications

  • Manufacturer: Emerson (Fisher-Rosemount)

  • Series: DeltaV Control System

  • Model / Part Number: KJ3002X1-BB1

  • Category: PLCs / Machine Control

  • Subcategory: Analog Output Module

  • Channels: 8 independently configurable outputs

  • Output Range: 4–20 mA nominal current loop

  • Resolution: 16-bit digital-to-analog conversion

  • Accuracy: ±0.15% of span at 25°C

  • Load Resistance: Up to 600 ohms at 24 VDC

  • Power Supply: 24 VDC (±10% tolerance)

  • Power Consumption: 2.8 W maximum

  • Update Rate: 50 ms per channel typical

  • Isolation: 250 VAC between channels and system

  • Operating Temperature: -40°C to +70°C

  • Relative Humidity: 5%–95% non-condensing

  • Dimensions: 12.5 cm (H) × 4.2 cm (W) × 10.5 cm (D)

  • Weight: Approx. 0.25 kg

Application Scenarios

  • Provides precise analog output control for DeltaV distributed control systems.

  • Suitable for industries such as power generation, petrochemical, and water treatment.

  • Ideal for applications requiring accurate current loop control for actuators, valves, and instrumentation.

FAQ

Q: How many output channels does this module support?  A: The KJ3002X1-BB1 supports eight independently configurable analog output channels.

Q: What is the resolution of the output signals?  A: It uses 16-bit digital-to-analog conversion for precise signal control.

Q: What is the maximum load resistance supported?  A: Up to 600 ohms at 24 VDC.

Q: How does this compare to input modules?  A: Unlike input modules, the KJ3002X1-BB1 is designed for output control, delivering stable 4–20mA signals to field devices.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more