Skip to content

What are you looking for?


You may also like

Emerson 396353-01-0 ControlWave Process Automation ControllerEmerson 396353-01-0 ControlWave Process Automation ControllerEmerson 396353-01-0 ControlWave Process Automation Controller
Emerson 396353-01-0 ControlWave Process Automation Controller
Emerson 396353-01-0 ControlWave Process Automation Controller
Emerson 396353-01-0 ControlWave Process Automation Controller

Emerson 396353-01-0 ControlWave Process Automation Controller


Only 10 left - Selling fast

PRODUCT SKU : 396353-01-0

PRODUCT TYPE : PLC Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Emerson 396353-01-0, also cataloged as the 396353-01-0 PLC Module, operates as a dedicated hardware component for process control execution and system communications within ControlWave platforms. Powered by an onboard AMD Elan SC520 microprocessor, the unit processes logic programs, manages SRAM, SDRAM, and flash memory allocations, and routes data traffic across RS-232 and Ethernet interfaces.

Hardware Specifications

Parameter Specification
Model 396353-01-0
Brand Emerson
Origin USA
Weight 1.25 kg
Dimensions Standard ControlWave slot envelope
Operating Temp -40 to +70 deg C
Power Consumption System backplane bus powered
Processing Unit AMD Elan SC520 microprocessor
Onboard Memory Integrated SRAM, SDRAM, and Flash memory
Communication Interfaces RS-232, Ethernet
Architecture Modular I/O expansion backplane architecture
Product Type PLC Modules

FOUNDATION Fieldbus and Channel Isolation

The controller platform integrates channel-to-channel isolation protocols across connected backplane expansion buses to prevent field ground loop currents from interfering with core processing operations. When integrated into distributed automation networks utilizing 4-20 mA HART loop protocol field devices and FOUNDATION Fieldbus segments, the internal circuitry isolates transient switching noise to maintain data integrity. Integrated cold junction compensation routines continuously compensate for ambient thermal shifts within local enclosure backplanes, securing accurate state determination across remote telemetry nodes.

Frequently Asked Questions

Q: Does the 396353-01-0 processor support hot-swapping while the backplane is energized?

A: No. System power to the main backplane must be switched off prior to installing or removing the CPU card to prevent logic corruption and electrical stress on edge-connector contacts.

Q: How is memory retained during primary power interruption?

A: Critical system parameters and runtime data are preserved in onboard SRAM via internal backplane backup power circuitry, while firmware binaries and boot code reside in non-volatile flash memory.

Q: What physical media are used for serial and network communications on the module interface?

A: Primary communication channels are established via dedicated front-panel connectors for serial RS-232 point-to-point connections and standard RJ-45 Ethernet network connections.

Field Installation Guidelines

  1. Disconnect main backplane power and isolate all external field wiring before inserting the card into the chassis slot.
  2. Align the module edge connector with the designated rack card guides within the ControlWave enclosure base.
  3. Slide the unit smoothly into the chassis slot until the card edge fully engages with the backplane connector socket.
  4. Tighten top and bottom retaining screws to secure the module against vibration and ensure frame grounding.
  5. Connect RS-232 serial cables and shielded Ethernet network lines to their respective communications ports.
  6. Verify that all communication line shielding is properly terminated to the main cabinet single-point ground bar before powering up the assembly.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Instrumentation Control Systems in Modern Industrial Automation

Understanding Instrumentation Control Systems in Modern Industrial Automation

An instrumentation control system (ICS) serves as the central nervous system of modern manufacturing plants and processing facilities. Engineers classify these setups as Electrical, Electronic, or Programmable Electronic Systems (E/E/PES). In practice, an ICS bridges the physical world of industrial machinery with digital decision-making tools. Therefore, understanding its architecture is essential for anyone working in factory automation, process control, or plant safety.

Read more
Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Electrical grounding is a complex engineering discipline. It requires deep knowledge of soil composition and conductor materials. National Electrical Code (NEC) Article 250 outlines these requirements clearly. Many engineers confuse grounding, earthing, and bonding. Grounding connects circuits to a common reference point. Earthing specifically links equipment directly to the planet. Bonding permanently joins metallic parts to ensure electrical continuity.

Read more
Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

According to IEC 62443, Industrial Automation and Control Systems (IACS) integrate personnel, hardware, and software. These components collectively influence the safety and reliability of any industrial process. Modern control systems allow extensive remote monitoring and operation. However, enabling remote capabilities introduces complex cybersecurity challenges. Therefore, facility operators must evaluate system functions carefully before expanding connectivity.

Read more