Skip to content

What are you looking for?


You may also like

Emerson 1C31107G01 Digital Input ModuleEmerson 1C31107G01 Digital Input ModuleEmerson 1C31107G01 Digital Input Module
Emerson 1C31107G01 Digital Input Module
Emerson 1C31107G01 Digital Input Module
Emerson 1C31107G01 Digital Input Module

Emerson 1C31107G01 Digital Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1C31107G01

PRODUCT TYPE : Digital Input Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete signal acquisition in Ovation control networks, the Emerson 1C31107G01 (1C31107G01 Digital Input Module) provides direct physical electrical execution for monitoring binary status signals. The module serves as the primary interface for processing 24 VDC and 48 VDC logic-level inputs from field sensors across the distributed control system architecture.

Hardware Specifications

Parameter Specification
Model 1C31107G01
Brand Emerson
Origin USA
Weight 0.30 kg
Dimensions 250 mm x 150 mm x 30 mm
Operating Temp 0 to 60 deg C
Power Consumption 24 VDC / 48 VDC
Input Type Digital Logic (24/48 V)

Channel-to-Channel Isolation

The 1C31107G01 incorporates galvanic channel-to-channel isolation to prevent the propagation of transient surges or common-mode electrical noise between discrete input channels. This isolation is necessary to maintain logic state integrity within the control loop, ensuring that electrical faults or high-frequency interference on one field device do not impact the status detection of adjacent channels. The circuitry is designed to reject typical field-side noise, providing a stable binary transition threshold for the controller.

Frequently Asked Questions (FAQ)

Q: Is this module compatible with both 24 VDC and 48 VDC logic signals without hardware adjustment?

A: The module is specified for 24/48 V operation; verify that field voltage levels are within the input threshold specifications of the specific board revision to ensure proper state detection.

Q: Does the module support hot-swapping within an active I/O rack?

A: Yes, the module supports hot-swapping; however, ensure that no active loop power is applied to the terminal block during the insertion or extraction process to prevent potential arcing at the backplane pins.

Field Installation Guidelines

  1. Ensure the control rack is powered down or in a non-critical maintenance state before installing the module.
  2. Confirm the backplane slot is free of dust or physical obstructions to ensure a secure electrical connection.
  3. Align the module with the guide rails and press firmly until the locking mechanism engages to prevent accidental dislodgement from vibration.
  4. Terminate digital input field wiring at the terminal block, ensuring that all conductors are properly ferruled to prevent stray wire strands from creating short circuits.
  5. Verify that field devices are wired to a common reference ground as defined in the system wiring diagrams to maintain consistent signal voltage thresholds.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Instrumentation Control Systems in Modern Industrial Automation

Understanding Instrumentation Control Systems in Modern Industrial Automation

An instrumentation control system (ICS) serves as the central nervous system of modern manufacturing plants and processing facilities. Engineers classify these setups as Electrical, Electronic, or Programmable Electronic Systems (E/E/PES). In practice, an ICS bridges the physical world of industrial machinery with digital decision-making tools. Therefore, understanding its architecture is essential for anyone working in factory automation, process control, or plant safety.

Read more
Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Electrical grounding is a complex engineering discipline. It requires deep knowledge of soil composition and conductor materials. National Electrical Code (NEC) Article 250 outlines these requirements clearly. Many engineers confuse grounding, earthing, and bonding. Grounding connects circuits to a common reference point. Earthing specifically links equipment directly to the planet. Bonding permanently joins metallic parts to ensure electrical continuity.

Read more
Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

According to IEC 62443, Industrial Automation and Control Systems (IACS) integrate personnel, hardware, and software. These components collectively influence the safety and reliability of any industrial process. Modern control systems allow extensive remote monitoring and operation. However, enabling remote capabilities introduces complex cybersecurity challenges. Therefore, facility operators must evaluate system functions carefully before expanding connectivity.

Read more