Skip to content

What are you looking for?


You may also like

396563-18-0 ControlWave Micro Analog Input/Output Module | Emerson396563-18-0 ControlWave Micro Analog Input/Output Module | Emerson396563-18-0 ControlWave Micro Analog Input/Output Module | Emerson
396563-18-0 ControlWave Micro Analog Input/Output Module | Emerson
396563-18-0 ControlWave Micro Analog Input/Output Module | Emerson
396563-18-0 ControlWave Micro Analog Input/Output Module | Emerson

396563-18-0 ControlWave Micro Analog Input/Output Module | Emerson


Only 10 left - Selling fast

PRODUCT SKU : 396563-18-0

PRODUCT TYPE : Analog Input/Output Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for analog field signal processing and local control loop execution in ControlWave Micro architectures, the Emerson 396563-18-0 (396563 Analog Input/Output Module) provides direct physical/electrical execution. It digitizes 6 single-ended analog inputs and drives 2 analog outputs while providing integrated serial and Ethernet network communication interfaces.

Hardware Specifications

Parameter Specification
Model 396563-18-0
Brand Emerson
Base Model 396563
Origin USA
Weight Approx. 0.35 kg
Dimensions Standard ControlWave Micro Module Footprint
Operating Temp -40 to 85 deg C
Power Consumption Low Power ARM Processor Powered
Analog Inputs 6 single-ended channels, configurable for 4-20 mA or 1-5 VDC
Analog Outputs 2 channels, configurable for 4-20 mA or 1-5 VDC (11 to 30 VDC external supply)
Onboard Processor ARM Microprocessor
Communication Ports 2 x RS-232, 1 x RS-485 asynchronous serial, 1 x 10/100 MB Ethernet RJ45
Surge Protection Limits Complies with IEEE C37.90-1978 and IEC 801-5 specifications
Mounting Format Panel or Wall-Mount Chassis Installation

4-20 mA HART Loop Protocol and Channel Isolation

The 396563-18-0 module routes 4-20 mA current and 1-5 VDC voltage loop signals through dedicated analog-to-digital converters, ensuring high precision for field transmitter measurements. Galvanic isolation and transient surge protection complying with IEEE C37.90-1978 and IEC 801-5 shield the onboard ARM microprocessor and communication interfaces from external field line disturbances. Dedicated channel-to-channel isolation limits noise coupling and cross-talk across active 4-20 mA HART loop protocol parameters on shared signal paths.

Frequently Asked Questions

Q: What power source is required to drive the two analog output channels on the 396563-18-0?

A: The analog outputs require an external direct current power supply operating within an 11 to 30 VDC voltage range.

Q: What communication interfaces are integrated directly onto the 396563-18-0 module?

A: The hardware includes two RS-232 serial ports, one RS-485 asynchronous serial port, and one 10/100 MB Ethernet port for host system and local I/O network communication.

Q: What surge immunity standards does the module meet for field wiring inputs?

A: Onboard protection circuitry complies with IEEE C37.90-1978 and IEC 801-5 surge suppression standards to protect internal logic from high-voltage transients.

Field Installation Guidelines

  1. Mount the module chassis securely to a flat panel or enclosure wall, ensuring space for airflow around the module frame.
  2. Verify that main power to the ControlWave Micro rack is isolated before inserting or removing the module from the backplane interface.
  3. Terminate analog field inputs and external 11-30 VDC output loop supplies to the terminal block, adhering to 4-20 mA or 1-5 VDC jumper configuration settings.
  4. Ground all Ethernet and serial interface cable shields to the main cabinet protective earth (PE) bus bar to suppress high-frequency electromagnetic noise.
  5. Maintain clear separation between field signal cables and high-voltage power lines inside cable ducting to prevent signal degradation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more