Skip to content

What are you looking for?


You may also like

GE DS200SDCCG4A Drive Control BoardGE DS200SDCCG4A Drive Control BoardGE DS200SDCCG4A Drive Control Board
GE DS200SDCCG4A Drive Control Board
GE DS200SDCCG4A Drive Control Board
GE DS200SDCCG4A Drive Control Board

GE DS200SDCCG4A Drive Control Board


Only 10 left - Selling fast

PRODUCT SKU : DS200SDCCG4A

PRODUCT TYPE : Controller Boards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed motor and drive regulation in Mark V control systems, the GE DS200SDCCG4A (DS200SDCCG4A Controller Board) provides direct physical execution of drive control, motor control, and co-motion processing tasks.

Hardware Specifications

Parameter Specification
Model DS200SDCCG4A
Brand GE (General Electric)
Origin USA
Operating Temp Standard industrial range
Microprocessors 80C186 (DCP), 80C196 (MCP), TMS320C25 (CMP)
Memory 4 x EPROM, 1 x EEPROM

Backplane Bus Communication and Deterministic Processing

The DS200SDCCG4A utilizes three distinct 16-bit microprocessors interconnected via dual-ported RAM (DPR) to ensure deterministic communication across the Mark V backplane. The Drive Control Processor (DCP) handles system-level operations, while the Motor Control Processor (MCP) manages inner-loop current regulation. For computationally intensive tasks, the Co-motion Processor (CMP) employs a TMS320C25 digital signal processor. Firmware flash compatibility is managed through onboard EPROM sockets, with site-specific calibration parameters stored within the U9 EEPROM. Precise address decoding and DMA control are maintained to ensure stable backplane bus communication velocity during complex ac/dc motor drive sequences.

Frequently Asked Questions

Q: Are the memory chips (EPROM/EEPROM) hot-swappable during system operation?

A: No. Memory chips located in the sockets must be replaced only while the card is powered down. Hot-swapping these components while the drive is active will cause immediate control failure and potential corruption of configuration data.

Q: How is the CMP processor utilized within the SDCC architecture?

A: The CMP (U35) is enabled only for motor control algorithms requiring processing power exceeding the capabilities of the MCP. It interfaces exclusively with its dedicated dual-ported RAM and EPROM to maintain high-speed execution of math-intensive control loops.

Field Installation Guidelines

  1. Ensure the control system is fully de-energized before inserting or removing the DS200SDCCG4A card from the Mark V cabinet rack.
  2. Verify that all jumper settings on the replacement board match the original configuration before installation to prevent conflicts in I/O scaling.
  3. Handle the board by the edges or the faceplate to avoid electrostatic discharge (ESD) damage to the microprocessors and memory chips.
  4. After installation, confirm that the EEPROM (U9) contains the correct site-specific parameters, as the new board will not be pre-configured with the specific tuning constants of the drive it is replacing.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more