Product Details

Configured for actuator interface in GS3/LQ control systems, the Woodward 9907-135 (9907-135 Driver Module) provides direct electrical execution of 4-20 mA demand signal conversion to output drive signals.

Hardware Specifications

Parameter Specification
Model 9907-135
Brand Woodward
Origin USA
Weight 0.38 kg
Dimensions 15.8 cm x 15.8 cm x 4.0 cm
Input Voltage 10-32 VDC
Input Signal 4-20 mA Demand

Actuator Loop Feedback Response and Thermal Heat Sink Dissipation Profiles

The 9907-135 driver module processes 4-20 mA demand signals to regulate output current for GS3/LQ series actuators. The module facilitates a stable actuator loop feedback response by maintaining precise current output proportional to the input command. Thermal heat sink dissipation profiles are managed by the module housing to support the internal power stage during operation across the specified 10-32 VDC input range. The circuit ensures minimal latency between command input and driver output, maintaining control accuracy for proportional valve or actuator positioning.

Frequently Asked Questions

Q: Can the 9907-135 be used with input voltages outside the 10-32 VDC range?

A: No. Operating the module outside the specified voltage range may result in internal component failure or erratic output behavior. Ensure the power source is regulated within the 10-32 VDC limits.

Q: Is the 4-20 mA input signal isolated from the module power ground?

A: The input is designed to receive standard 4-20 mA control signals. Standard practice requires ensuring the signal source and the driver module power supply share a common reference point if isolation is not explicitly defined in the site-specific control schematic.

Field Installation Guidelines

  • Mounting: Secure the module using the provided mounting holes. Maintain adequate clearance around the 15.8 cm x 15.8 cm x 4.0 cm footprint to facilitate convective cooling.
  • Wiring: Terminate field connections using the screw clamp terminals. Ensure wire gauges are appropriate for the 10-32 VDC power draw and 4-20 mA signal transmission.
  • Shielding: Use shielded twisted-pair cables for the 4-20 mA demand signal input. Terminate shields at the control cabinet ground to prevent electromagnetic interference from skewing the command signal.
  • Inspection: Verify terminal tightness after initial installation to prevent intermittent connections that could cause signal loss or erratic actuator positioning.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more