Skip to content

What are you looking for?


You may also like

3BHE036346R0101 ABB XZ C825 A101 Processing Card3BHE036346R0101 ABB XZ C825 A101 Processing Card3BHE036346R0101 ABB XZ C825 A101 Processing Card
3BHE036346R0101 ABB XZ C825 A101 Processing Card
3BHE036346R0101 ABB XZ C825 A101 Processing Card
3BHE036346R0101 ABB XZ C825 A101 Processing Card

3BHE036346R0101 ABB XZ C825 A101 Processing Card


Only 10 left - Selling fast

PRODUCT SKU : XZ C825 A101 3BHE036346R0101

PRODUCT TYPE : Digital I/O Cards

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete signal routing and deterministic serial communication in DCS backplane architectures, the ABB 3BHE036346R0101 (XZ C825 A101 Processing Card) provides direct physical/electrical execution. It directly processes binary field logic across 16 discrete input channels and 16 discrete output channels while maintaining high-speed serial feedback over an RS-485 physical interface. Operating on a nominal 24 VDC external power supply, the unit consumes 15 W under full load conditions and provides continuous signal processing within an operational envelope of -20 deg C to +60 deg C.

Hardware Specifications

Parameter Specification
Model 3BHE036346R0101
Sub-Model XZ C825 A101
Brand ABB
Origin Switzerland
Weight 180 g
Dimensions 105 x 50 x 26 mm
Operating Temp -20 deg C to +60 deg C
Power Consumption 15 W
Operating Voltage 24 VDC
Communication Interface RS-485
I/O Channel Density 16 Input / 16 Output Channels

Backplane Bus Communication Velocity and Density Scaling

The module leverages high-speed backplane bus communication velocity to manage real-time updates across all 32 discrete channels without introducing processing jitter. Integrated protocol engines enforce deterministic transmission over the RS-485 interface, stabilizing multi-drop network topologies under heavy I/O density scaling. Low-latency internal firmware flash compatibility ensures firmware integrity during system updates, maintaining synchronization between field-side input states and rack-level controller logic.

Frequently Asked Questions

Q: What are the physical grounding requirements for the RS-485 interface on this module?

A: The RS-485 serial connection requires a dedicated shielded twisted-pair cable. The cable shield must be grounded at a single end to the cabinet earth ground bar to prevent ground loops, and a terminal resistance of 120 ohms must be enabled at the physical ends of the bus segment.

Q: What is the recommended operational power supply tolerance for the 24 VDC input?

A: The module accepts a standard 24 VDC supply with a typical operating tolerance of +/- 10%. Power input should be conditioned using an external regulated industrial power supply with overcurrent and surge protection to prevent operational interruptions or thermal stress.

Field Installation Guidelines

  • Mount the card securely in the dedicated subrack slot, ensuring top and bottom card retainers are fully engaged before applying power.
  • De-energize all field-side power sources and system backplanes prior to physical insertion or removal of the card.
  • Maintain a minimum physical separation of 100 mm between low-voltage DC/signal wiring and high-voltage AC power conductors within the wire ducting.
  • Ensure field wiring terminals are torqued to specified terminal block limits and strain-relief mechanisms are secured.
  • Verify cabinet thermal management guarantees ambient temperatures surrounding the card remain strictly between -20 deg C and +60 deg C during continuous operation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more