The Honeywell 80363969-100, also cataloged as the 80363969-100 Analog Output Processor Module, operates as a dedicated hardware component for converting digital control signals to analog outputs within Honeywell TDC 3000 and Process Manager architectures. It drives 16 isolated channels outputting 4-20 mA analog current directly to field positioning devices and analog control loops.

Hardware Specifications

Parameter Specification
Model 80363969-100
Brand Honeywell
Origin USA
Weight 1.0 kg
Dimensions 40 mm x 260 mm x 220 mm
Operating Temp 0 deg C to 60 deg C
Power Consumption Standard Backplane Load
Output Channels 16 isolated channels
Output Range 4-20 mA analog current
Compatible Terminal Boards MU-TAOY22, MU-TAOY52, MC-TAOY22, MC-TAOY52

Channel-to-Channel Isolation and Loop Protocol Response

The Honeywell 80363969-100 incorporates internal optical decoupling across all 16 current loops to maintain channel-to-channel isolation. This galvanic barrier protects internal microprocessor logic against field ground loops and high-voltage electrical surges. When operating with 4-20 mA HART loop protocol field positioners, the digital-to-analog converter stage provides continuous loop impedance management to stabilize signal conversion over extended cable distances.

Frequently Asked Questions

Q: Are terminal connections made directly to the front face of the 80363969-100 module?

A: No. Field cabling connects to compatible external terminal assemblies such as the MU-TAOY22, MU-TAOY52, MC-TAOY22, or MC-TAOY52, which link to the module via dedicated multi-conductor cables.

Q: Can an individual 4-20 mA output channel be configured as a voltage output?

A: No. The internal digital-to-analog conversion circuitry is designed strictly for 4-20 mA current loop driving and does not provide native voltage output options.

Field Installation Guidelines

  1. Turn off main rack power and field loop power supplies prior to seating or removing the module from the chassis slot.
  2. Align the module circuit board with the chassis card guides and push firmly until the rear connectors seat securely into the backplane.
  3. Fasten the module retaining screws to ensure proper chassis grounding and mechanical retention under operational vibration.
  4. Route field signal cables through grounded, shielded conduits and separate them from high-voltage AC power wiring to prevent noise coupling.
  5. Verify that shield drain wires are tied to a single-point system ground block at the cabinet cable entrance.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more