Product Details

The Honeywell 900C70S-0360-00, also cataloged as the 900C70S CPU Module, operates as a dedicated hardware component for SIL-rated process control, function block execution, and remote I/O processing within ControlEdge HC900 platforms. Powered by a 5 VDC backplane supply drawing up to 1350 mA, the unit processes discrete and analog control loops across dual RS-485 serial interfaces and triple 10/100 Base-T Ethernet ports. It handles deterministic function block processing while maintaining real-time communication links to local and expansion racks.

Hardware Specifications

Parameter Specification
Model 900C70S-0360-00
Brand Honeywell
Origin USA
Weight 0.85 lbs (0.39 kg)
Dimensions Standard ControlEdge HC900 CPU slot footprint
Operating Temp 0 to 60 deg C
Power Consumption 1350 mA maximum at 5 VDC backplane
Functional Capability Up to 5000 function blocks (SIL-rated)
Serial Interfaces 2 x RS-485 serial ports
Ethernet Interfaces 3 x 10/100 Base-T Ethernet ports
I/O Processing Remote I/O rack expansion supported

Channel-to-Channel Isolation & DCS Network Performance

The Honeywell 900C70S-0360-00 module integrates isolated physical communication transceivers across its triple 10/100 Base-T Ethernet and dual RS-485 interfaces, decoupling central execution logic from field network noise. Internal isolation circuitry protects CPU memory registers during high-speed data transmission between remote I/O racks and process controllers. This isolated interface layer maintains signal integrity for connected analog modules handling 4-20 mA HART loop protocol field instruments and temperature sensors.

Frequently Asked Questions

Q: How is the primary power supplied to the 900C70S-0360-00 CPU module?

A: The module draws power directly from the 5 VDC system backplane bus regulated by the rack power supply, consuming up to 1350 mA under maximum processing load.

Q: Can the 900C70S-0360-00 CPU module be removed or inserted while the rack is powered?

A: Removal and insertion under power (RIUP) must comply with ControlEdge HC900 system rules; system power off is recommended during CPU hardware swaps to prevent backplane bus communication faults.

Field Installation Guidelines

  • Seat the 900C70S-0360-00 securely into the dedicated CPU slot of the HC900 controller rack, ensuring top and bottom retaining levers lock into the frame.
  • Connect shielded twisted-pair cables to the dual RS-485 ports, ensuring termination resistors are properly set at both ends of the serial bus loop.
  • Utilize Category 5e or higher shielded Ethernet cables for the three 10/100 Base-T ports to maintain isolated data links to network switches and remote I/O chassis.
  • Bond the controller rack chassis to protective earth (PE) using a dedicated grounding conductor before energizing the assembly.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more