Skip to content

What are you looking for?


You may also like

16644993-001 Honeywell C300 Controller Module16644993-001 Honeywell C300 Controller Module16644993-001 Honeywell C300 Controller Module
16644993-001 Honeywell C300 Controller Module
16644993-001 Honeywell C300 Controller Module
16644993-001 Honeywell C300 Controller Module

16644993-001 Honeywell C300 Controller Module


Only 10 left - Selling fast

PRODUCT SKU : 16644993-001

PRODUCT TYPE : Controller Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 16644993-001, also cataloged as the 16644993 C300 Controller Module, operates as a dedicated hardware component for real-time control strategy execution and system diagnostics within Honeywell Experion PKS platforms. It handles direct execution of control logic and manages high-speed data exchanges across Fault Tolerant Ethernet (FTE) and I/O Link networks.

Hardware Specifications

Parameter Specification
Model 16644993-001
Brand Honeywell
Origin USA
Weight 1.0 to 1.5 kg
Dimensions Standard C300 chassis form factor
Operating Temp 0 to +60 deg C
Power Consumption System chassis powered
Product Type C300 Controller Module
Processor High-speed embedded processor for real-time control
System Compatibility Honeywell Experion PKS, Universal I/O, Series 8 I/O
Communication Interfaces Fault Tolerant Ethernet (FTE), I/O Link
Redundancy Support Configurable redundant pairs with automatic failover
Mounting Chassis-mounted (e.g., FC-CPCHAS-0001) with keyed connectors

Process Control and DCS Instrumentation Characteristics

The 16644993-001 controller processes field data across I/O Link backplane channels that support 4-20 mA HART loop protocol device passthrough. Interfacing with Series 8 and Universal I/O subsystems, the module relies on channel-to-channel isolation at the I/O rack level to eliminate ground loops and isolate common-mode voltage fluctuations. Temperature processing blocks within the controller's runtime environment evaluate cold junction compensation (CJC) metrics provided by thermocouple input modules. Built-in network drivers maintain deterministic connectivity to FOUNDATION Fieldbus and Profibus PA interface gateways through Fault Tolerant Ethernet (FTE) trunks.

Frequently Asked Questions

Q: How is dual-redundant tracking managed between paired 16644993-001 modules?

A: Redundancy is established by pairing two 16644993-001 modules on a C300 chassis. Memory tables, execution state, and clock cycles are mirrored over dedicated sync channels to allow seamless failover without interrupting controller output states.

Q: What are the physical constraints when inserting the 16644993-001 into a C300 chassis?

A: The module utilizes keyed connectors for tool-less chassis mounting (such as slot location FC-CPCHAS-0001), preventing physical misalignment during installation or hot-swap procedures.

Field Installation Guidelines

  1. Confirm the target chassis slot on the C300 baseplate (e.g., FC-CPCHAS-0001) is clean and free of particulate debris before seating.
  2. Align the module card edges with the chassis guide slots and apply steady, level pressure until the keyed connectors engage fully.
  3. Lock retaining tabs onto the chassis frame to ensure structural stability against operational vibration.
  4. Verify that Fault Tolerant Ethernet (FTE) network cables (FTE A and FTE B trunks) are connected to the designated redundant ports on the chassis backplane.
  5. Apply backplane power and observe onboard status LEDs to verify successful self-diagnostics and firmware loading prior to assigning controller execution tasks.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more