Skip to content

What are you looking for?


You may also like

Yokogawa VI451-10 Communication Module | CENTUM Vnet/IPYokogawa VI451-10 Communication Module | CENTUM Vnet/IPYokogawa VI451-10 Communication Module | CENTUM Vnet/IP
Yokogawa VI451-10 Communication Module | CENTUM Vnet/IP
Yokogawa VI451-10 Communication Module | CENTUM Vnet/IP
Yokogawa VI451-10 Communication Module | CENTUM Vnet/IP

Yokogawa VI451-10 Communication Module | CENTUM Vnet/IP


Only 10 left - Selling fast

PRODUCT SKU : VI451-10

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa VI451-10 serves as a high-performance communication interface within the CENTUM Distributed Control System (DCS) architecture. This module facilitates real-time data exchange across the control network, ensuring seamless synchronization between field control stations and human interface stations. Engineered for industrial resilience, the VI451-10 provides the critical backbone for high-speed plant telemetry and deterministic communication.

Technical Specifications

The VI451-10 combines Japanese engineering precision with rugged hardware standards to maintain system uptime:

Feature Specification
Manufacturer Yokogawa
Model VI451-10
Product Type Communication Module
Input Power Supply 100 to 120 V AC
Protection Level IP54 (Dust & Splash Resistant)
Max. Input Current 20 A (Peak) / 6 A (Continuous)
Dimensions 13.2 cm * 5.3 cm * 6.5 cm
Weight 0.75 kg
Country of Origin Japan
Condition 100% Brand New and Original

Engineering Advantages

  • IP54 Environmental Protection: The VI451-10 features an IP54-rated housing. This protection level shields internal circuitry from dust ingress and water splashes, allowing for installation in demanding process environments where standard modules might fail.

  • High-Current Surge Capacity: The module architecture manages input currents up to 20 A. This robust electrical design allows the hardware to withstand localized power fluctuations and start-up surges without tripping safety interlocks or corrupting communication packets.

  • Compact Integration: With a slim footprint of 13.2 cm, the VI451-10 fits easily into high-density I/O nests. This compact form factor solves the common industrial pain point of limited cabinet space, enabling engineers to expand network capacity without upgrading enclosure sizes.

  • Japanese Precision Engineering: Manufactured in Japan, this module adheres to the highest QC standards. The gold-plated connectors and high-grade capacitors ensure long-term signal integrity and prevent oxidation in humid or corrosive plant atmospheres.

FAQs

  • Is the Yokogawa VI451-10 supplied as new or refurbished?

    We supply this unit exclusively as 100% Brand New and Original. Every module arrives in its factory-sealed Yokogawa packaging, ensuring you receive a component with zero previous runtime and full manufacturer reliability.

  • What does the IP54 rating mean for my installation?

    The IP54 rating ensures the module remains protected against limited dust ingress and water spray from any direction. While we still recommend mounting it inside an industrial cabinet, the VI451-10 provides an extra layer of safety against the environmental contaminants often found in chemical and power plants.

  • Does this module support 220V AC input?

    No. The VI451-10 specifically requires a 100 to 120 V AC input. Connecting this module to a 220V source will cause immediate hardware failure. Always verify your power distribution unit (PDU) voltage before seating the module in the nest.

  • Can I replace a legacy communication module with the VI451-10?

    The VI451-10 typically serves modern CENTUM systems. Before replacement, verify that your current backplane and software revision support the -10 variant. The module’s 6.5 cm depth fits standard RIO/FIO slots, facilitating a "drop-in" upgrade for compatible systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more