PRODUCT SKU : VE4022

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for fieldbus integration in DeltaV control networks, the Emerson VE4022 (VE4022 Profibus DP Interface Card) provides direct physical/electrical execution of deterministic Profibus DP communication across M-Series platforms.

Hardware Specifications

Parameter Specification
Model VE4022
Brand Emerson
Origin USA
Weight 0.91 kg (2.00 lbs)
Dimensions M-Series module form factor
Operating Temp Not specified
Power Consumption System-powered via backplane
Connectivity Profibus DP protocol
Termination Simplex termination block

Process Control: Profibus DP Connectivity

The VE4022 serves as a dedicated communication gateway, facilitating the integration of Profibus DP-compliant field devices into the DeltaV control architecture. This card manages the deterministic cyclic exchange of process data and allows for the acyclic parameterization of field instruments. The internal bus interface is isolated from the field communication port, ensuring that potential ground loops or electrical surges at the Profibus network segment do not interfere with the controller's backplane communication.  The module supports high-speed baud rate synchronization and enforces protocol-compliant bus timing, maintaining strict master-slave communication cycles.

Frequently Asked Questions (FAQ)

Q: Does the VE4022 card support redundant operation?

A: The VE4022 is provided with a simplex termination block, intended for non-redundant Profibus DP master configurations. For redundant fieldbus requirements, a dual-redundant card and carrier configuration must be utilized.

Q: Is the Profibus DP port electrically isolated?

A: Yes. The Profibus port on the VE4022 is galvanically isolated from the M-Series backplane. This isolation is mandatory to protect the internal controller logic from electrical noise prevalent in extended Profibus fieldbus segments.

Field Installation Guidelines

  • Mounting: Install the VE4022 into the designated slot on the M-Series I/O carrier. Ensure the simplex termination block is fully seated to maintain the integrity of the signal path and the mechanical grounding of the module housing.

  • Bus Termination: Profibus DP networks require active termination at both ends of the physical segment. Ensure that the bus segments connected to the VE4022 are terminated according to the Profibus standard (using 220 Ohm bias resistors) to prevent signal reflection.

  • Shielding: Terminate the Profibus cable shield at the cabinet entry point using a low-impedance grounding bar. Continuous shielding is mandatory to maintain data integrity across the high-speed bus.

  • Verification: After installation, verify the network configuration in the DeltaV engineering station and perform a diagnostic scan of the field devices to confirm communication status and the absence of frame errors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more