Overview  

The GE UR7DH Inter-Relay Communications Module is designed for the Multilin Universal Relay (UR) series. It enables high-speed communication between relays, ensuring reliable coordination and protection across power systems. With integrated diagnostics and robust construction, the UR7DH is built for dependable performance in demanding industrial and utility environments.

Technical Specifications

  • Manufacturer: General Electric (GE)

  • Model: UR7DH

  • Type: Inter-Relay Communications Module

  • Communication Channel: Single 1300 nm, single-mode LASER channel

  • Compatibility: Fully compatible with GE Multilin UR series relays

  • Monitoring: Integrated channel health monitoring for diagnostics

  • Power Supply: Powered directly through the connected relay unit

  • Frequency: 50/60 Hz

  • Operating Temperature: -40°C to +70°C (-40°F to +158°F)

  • Dimensions: 152 mm (L) × 178 mm (W) × 38 mm (H)

  • Weight: 0.77 kg

Key Features

  • High-speed optical communication for relay coordination

  • Integrated diagnostics for channel health monitoring

  • Powered through relay unit, eliminating external supply needs

  • Compact design for easy installation in relay systems

  • Rugged construction for reliable operation in harsh environments

Applications

  • Substation automation requiring relay-to-relay communication

  • Power system protection and coordination

  • Industrial control systems with distributed relay networks

  • Mission-critical environments needing secure optical communication

FAQ

  • Q: What type of communication channel does the UR7DH use?  A: It uses a single-mode LASER channel at 1300 nm.

  • Q: How is the UR7DH powered?  A: It is powered through the connected relay unit, requiring no external supply.

  • Q: Does the UR7DH provide diagnostics?  A: Yes, it includes integrated channel health monitoring for diagnostics.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more