Triplex 4351A TCM Terminal Communication Module Copper Ethernet InterfaceTriplex 4351A TCM Terminal Communication Module Copper Ethernet InterfaceTriplex 4351A TCM Terminal Communication Module Copper Ethernet Interface
Triplex 4351A TCM Terminal Communication Module Copper Ethernet Interface
Triplex 4351A TCM Terminal Communication Module Copper Ethernet Interface
Triplex 4351A TCM Terminal Communication Module Copper Ethernet Interface

Triplex 4351A TCM Terminal Communication Module Copper Ethernet Interface


Only 10 left - Selling fast

PRODUCT SKU : 4351A

PRODUCT TYPE : Ethernet Interface Module

PRODUCT VENDOR : Triconex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 4351A Terminal Communication Module (TCM) acts as the primary communication bridge for high-availability industrial control systems. It facilitates seamless data exchange between the controller and external networks via dual copper Ethernet ports. This module integrates critical diagnostic protocols and high-speed serial processing to ensure real-time telemetry and peer-to-peer synchronization in mission-critical environments. We supply this unit as 100% brand new and original factory stock.

Technical Specifications

Feature Specification
Network Interface 2 x 10/100BaseT Ethernet (RJ-45)
Serial Ports 4 x RS-232/RS-485 (DB-9)
Port Isolation 500 VDC
Protocol Support Modbus TCP/IP, TSAA, TriStation, SNTP, Jet Direct
Serial Speed Up to 115.2 Kbps per port
Power Requirement 24V DC
Physical Weight Approx. 0.5 kg

Engineering Advantages

  • Deterministic Synchronization: The NET 1 port executes hardware-level Peer-to-Peer Time Synchronization. This eliminates jitter across distributed nodes, ensuring that time-stamped events remain accurate within complex automated sequences.

  • Robust Electrical Isolation: With 500 VDC isolation on communication ports, the 4351A shields the internal logic from ground loops and transient voltage spikes common in heavy industrial motor-drive environments.

  • Simplified Network Printing: The native Jet Direct support allows the module to trigger automated reports and alarm logs directly to network printers, bypassing the need for an intermediate PC workstation.

  • Versatile Modbus Implementation: The module supports extensive Modbus functions (01 through 16). This allows engineers to perform everything from simple coil reads to complex multiple-register presets, making it compatible with a vast array of legacy and modern SCADA systems.

FAQs

  • What is the primary difference between the 4351A and the 4352A?

    The 4351A utilizes copper Ethernet (RJ-45) for standard local networking, while the 4352A employs fiber-optic (MTRJ) connectors for long-distance runs or areas with extreme electromagnetic interference.

  • Does the 4351A support both Master and Slave Modbus configurations?

    Yes. The module supports Modbus TCP/IP in both Master and Slave modes, providing the flexibility to either pull data from field devices or report data to a higher-level HMI.

  • What do the 'FIRM' and 'ACTIVE' LEDs indicate during operation?

    The ACTIVE LED signals that the module is currently controlling the I/O bus, while the FIRM LED indicates the status of the resident firmware—essential for verifying successful field updates or identifying initialization errors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more