Product Overview

The Schneider Electric TSXMAP1074 serves as a specialized MAPWAY communication interface for legacy Modicon PLC architectures. This module facilitates high-level industrial networking, allowing different controllers and supervisory systems to exchange data across the MAPWAY protocol. Despite its status as a discontinued part from the manufacturer, it remains a critical component for maintaining the operational integrity of established machine control systems. We supply this hardware as 100% brand new original equipment, ensuring that your facility bypasses the risks associated with used or refurbished surplus.

Technical Specifications

The TSXMAP1074 features a rugged design intended for direct rack mounting within Modicon PLC environments.

  • Manufacturer: Schneider Electric / Modicon

  • Model Number: TSXMAP1074 (TSX-MAP-1074)

  • Product Type: Communication Module

  • Protocol: MAPWAY

  • Physical Format: Standard PLC Rack Module

  • Application: PLCs / Machine Control

  • Net Weight: 2.51 lbs (1.14 kg)

  • Mounting: Modular Rack Installation

Engineering Advantages

  • Legacy Infrastructure Preservation: The TSXMAP1074 allows engineers to maintain existing MAPWAY network topologies without undergoing a full, costly system migration. It integrates seamlessly into legacy racks, extending the service life of proven automation assets.

  • Deterministic Data Exchange: This module manages complex communication tasks independently of the main CPU. By offloading the networking overhead, the TSXMAP1074 ensures that the PLC processor maintains high-speed logic execution without communication-induced jitter.

  • Rugged Mechanical Reliability: Weighing 2.51 lbs, this module features a heavy-duty industrial casing. This robust build protects internal delicate electronics against the high-vibration and electromagnetic interference (EMI) common in heavy manufacturing environments.

  • Simplified Integration: The module utilizes standard Modicon rack connectors. This design enables "plug-and-play" replacement for failed units, requiring minimal physical reconfiguration during emergency maintenance windows.

FAQs

  • Is the TSXMAP1074 compatible with modern Schneider EcoStruxure systems?

    The TSXMAP1074 specifically supports legacy Modicon MAPWAY networks. While modern systems often use Ethernet/IP or Modbus TCP, this module serves the critical role of maintaining older infrastructure that relies on the MAPWAY protocol for machine-to-machine communication.

  • How does this module handle internal diagnostics?

    The module executes self-tests upon power-up. Front-panel status indicators provide immediate visual feedback regarding network activity and module health, allowing technicians to isolate communication faults quickly.

  • Does this unit come in original factory packaging?

    Yes. We guarantee that each TSXMAP1074 we ship is 100% Brand New. It arrives in its original factory box with all original protective materials, ensuring the unit remains in pristine condition despite the manufacturer's discontinued status.

  • What precautions should I take during installation?

    Always verify that the PLC rack power is OFF before inserting or removing the TSXMAP1074. Ensure the module seats firmly into the backplane connectors to prevent intermittent communication errors caused by physical vibration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more