Skip to content

What are you looking for?


You may also like

Schneider Electric 140NRP95400 Modicon Quantum Multi-Mode Fiber Optic RepeaterSchneider Electric 140NRP95400 Modicon Quantum Multi-Mode Fiber Optic RepeaterSchneider Electric 140NRP95400 Modicon Quantum Multi-Mode Fiber Optic Repeater
Schneider Electric 140NRP95400 Modicon Quantum Multi-Mode Fiber Optic Repeater
Schneider Electric 140NRP95400 Modicon Quantum Multi-Mode Fiber Optic Repeater
Schneider Electric 140NRP95400 Modicon Quantum Multi-Mode Fiber Optic Repeater

Schneider Electric 140NRP95400 Modicon Quantum Multi-Mode Fiber Optic Repeater


Only 10 left - Selling fast

PRODUCT SKU : 140NRP95400

PRODUCT TYPE : Fiber Optic Repeater

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 140NRP95400 provides high-speed signal regeneration and media conversion for the Schneider Electric Modicon Quantum platform. This fiber optic repeater facilitates long-distance communication between racks by converting coaxial electrical signals into multi-mode optical signals. It extends the reach of the Quantum network while providing total electrical isolation between drops. We supply this module as 100% Brand New and Original, ensuring peak data integrity for large-scale distributed control systems.

Technical Specifications

The 140NRP95400 utilizes a 820 nm wavelength to achieve impressive transmission distances across various fiber types:

  • Optic Fiber Type: Multi-mode

  • Wavelength: 820 nm

  • Optical Ports: 2 x ST Connectors

  • Electrical Ports: 1 x Coaxial Connector

  • Maximum Distance: 9842.5 ft (3000 m) using 62.5/125 µm fiber

  • Receiver Sensitivity: -30 dBm

  • Dynamic Range: 20 dB

  • Rise/Fall Time: 20 ns

  • Bus Current Requirement: 700 mA

  • Power Dissipation: 5 W

  • Material: Polycarbonate (PC)

  • Weight: 1.22 lb (0.554 kg)

Engineering Advantages

  • Extended Network Range: This repeater overcomes the physical limitations of copper cabling. It permits a distance of up to 3000 meters between transceivers, enabling the control of remote I/O racks in separate buildings or distant sections of a plant.

  • Immunity to Electromagnetic Interference: By utilizing multi-mode fiber optics, the 140NRP95400 eliminates ground loops and protects the data stream from high-voltage EMI and RFI. This makes it essential for communications in power plants, substations, and environments with heavy motor traffic.

  • Redundant Optical Paths: The dual ST fiber ports allow for flexible network topologies. Engineers can implement star or bus configurations to enhance network reliability and provide alternate data paths for the Quantum bus.

  • Comprehensive Diagnostic Array: Seven integrated LEDs provide instantaneous status updates. Dedicated indicators monitor coaxial communication, optical link health, internal faults (ERR), and module readiness (RDY), significantly reducing the time required to diagnose network interruptions.

  • Fast Signal Processing: A 20 ns rise/fall time ensures that the repeater introduces negligible latency into the Quantum bus. This maintains the high-speed synchronization necessary for real-time PAC performance and time-critical process control.

FAQs

  • What fiber optic connectors does the 140NRP95400 use?

    The module features two standard ST (Straight Tip) connectors for the optical interface and one coaxial connector for the electrical drop.

  • Can I mix different fiber sizes with this repeater?

    The 140NRP95400 supports 50/125 µm, 62.5/125 µm, and 100/140 µm multi-mode fibers. However, you must ensure that the cable and connectors remain consistent throughout a single link segment to avoid excessive signal attenuation.

  • Does this module require external power?

    No. The 140NRP95400 draws its operating power directly from the Quantum backplane bus, requiring 700 mA at 5 V DC.

  • Is this a current Schneider Electric product or a refurbished unit?

    We guarantee this is a 100% Brand New original factory product. It ships in original Schneider Electric packaging with the latest hardware revisions to ensure compatibility with your existing Quantum platform.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more