PS69-DPS | ProSoft CompactLogix PROFIBUS DP-V1 Slave Communication ModulePS69-DPS | ProSoft CompactLogix PROFIBUS DP-V1 Slave Communication ModulePS69-DPS | ProSoft CompactLogix PROFIBUS DP-V1 Slave Communication Module
PS69-DPS | ProSoft CompactLogix PROFIBUS DP-V1 Slave Communication Module
PS69-DPS | ProSoft CompactLogix PROFIBUS DP-V1 Slave Communication Module
PS69-DPS | ProSoft CompactLogix PROFIBUS DP-V1 Slave Communication Module

PS69-DPS | ProSoft CompactLogix PROFIBUS DP-V1 Slave Communication Module


Only 10 left - Selling fast

PRODUCT SKU : PS69-DPS

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The PS69-DPS module from ProSoft Technology is a PROFIBUS DP-V1 slave communication interface designed for Allen Bradley CompactLogix systems. It provides reliable PROFIBUS connectivity with robust compliance to international standards, making it suitable for demanding industrial environments.

Key Specifications

  • Manufacturer: Allen Bradley / ProSoft Technology

  • Model: PS69-DPS

  • Part Number: PS69-DPS

  • Product Type: PROFIBUS DP-V1 Slave Communication Module

  • Processor: EC1-160P with integrated ASPC2

  • PROFIBUS Interface: RS-485, up to 12 Mbps, potential-free (EN 50170 compliant)

  • Diagnostic Interface: RS-232, PS/2 Mini-DIN female connector, 9600 baud, non-isolated

  • Power Supply: 260 mA @ +5 V ±5%

  • Power Supply Distance Rating: 6 (no more than six modules away from the 1769 power supply)

  • Module Format: Standard 1769 single-slot module

  • Electromagnetic Compliance:

    • Burst: EN 61000-4-4, 2 kV, 5 kHz

    • Surge: EN 61000-4-5, 2 kV common mode, 1 kV differential mode

    • ESD: EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect

    • Radiated/Conducted Immunity: EN 61000-4-3, 10 V/m (30–1000 MHz, 80% AM, 1 kHz sinewave); EN 61000-4-6, 10 V (0.15–30 MHz)

    • Radiated/Conducted Emission: EN 55011 Class A

  • Mechanical Resistance:

    • Vibration: IEC 600068-2-6, 10–150 Hz, ±0.75 mm, ±1 g, 1 octave/min

    • Shock: IEC 600068-2-27, 15 g, 11 ms

  • Operating Temperature: 0–60°C (32–140°F)

  • Storage Temperature: –40–85°C (–40–185°F)

  • Relative Humidity: 5–95% non-condensing

Core Features

  • PROFIBUS DP-V1 slave functionality for CompactLogix systems

  • Integrated diagnostic interface for troubleshooting and monitoring

  • Compliance with EN and IEC standards for EMC, ESD, surge, and vibration resistance

  • Compact single-slot design for efficient rack installation

  • Reliable operation across industrial temperature and humidity ranges

Application Scenarios

  • Integration of PROFIBUS DP-V1 slave devices into CompactLogix controllers

  • SCADA and distributed control systems requiring PROFIBUS connectivity

  • Industrial automation environments in petrochemical, food processing, and manufacturing sectors

FAQ

  • Q: What is the maximum PROFIBUS data rate supported?  A: Up to 12 Mbps.

  • Q: How far can the module be installed from the power supply?  A: No more than six modules away from the 1769 power supply.

  • Q: Does the module include diagnostic capabilities?  A: Yes, via an RS-232 Mini-DIN interface.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more