Skip to content

What are you looking for?


You may also like

ProSoft | MVI46-DFNT | SLC 500 EtherNet/IP Client/Server Communication ModuleProSoft | MVI46-DFNT | SLC 500 EtherNet/IP Client/Server Communication ModuleProSoft | MVI46-DFNT | SLC 500 EtherNet/IP Client/Server Communication Module
ProSoft | MVI46-DFNT | SLC 500 EtherNet/IP Client/Server Communication Module
ProSoft | MVI46-DFNT | SLC 500 EtherNet/IP Client/Server Communication Module
ProSoft | MVI46-DFNT | SLC 500 EtherNet/IP Client/Server Communication Module

ProSoft | MVI46-DFNT | SLC 500 EtherNet/IP Client/Server Communication Module


Only 10 left - Selling fast

PRODUCT SKU : MVI46-DFNT

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The MVI46-DFNT module from ProSoft Technology is an EtherNet/IP client/server communication interface designed for Allen Bradley SLC 500 controllers. It provides seamless integration between SLC processors and Ethernet-based networks, supporting up to 100 user-defined commands and 4000 registers for flexible data exchange.

Key Specifications

  • Manufacturer: Allen Bradley / ProSoft Technology

  • Model: MVI46-DFNT

  • Part Number: MVI46-DFNT

  • Product Type: EtherNet/IP Client/Server Module

  • Product Line: SLC 500

  • Weight: 3.00 lbs (1.36 kg)

  • Module Width: Single slot

  • Compatible Controllers: SLC 5/02 and newer M0/M1 capable processors

  • Rack Type: Local or remote installation supported

  • Backplane Current Load: 800 mA @ 5 VDC

  • Interface: 10/100 Mbps Ethernet-compatible

  • Ports: 3 total (CFG port, configuration connector, Ethernet/IP port)

  • Data Transfer Method: Ladder Logic integration

  • SLC Registers: Up to 4000 registers

  • User-defined Commands: 100 maximum

  • Operating Shock: 30 g

  • Vibration Resistance: 5 g, 10–500 Hz

  • Isolation Voltage: 50 V continuous, basic insulation type (fieldbus to system)

  • LED Indicators: Module status, backplane transfer, application status, serial activity (debug port), Ethernet link/activity, error status

  • Operating Temperature: 0–60°C (32–140°F)

  • Storage Temperature: –40–85°C (–40–185°F)

  • Relative Humidity: 5–95% non-condensing

Core Features

  • Provides EtherNet/IP client/server communication for SLC 500 systems

  • Supports up to 100 user-defined commands for flexible integration

  • Ladder Logic-based data transfer for seamless PLC communication

  • Diagnostic LEDs for real-time monitoring of module and network status

  • Compact single-slot design for efficient rack installation

Application Scenarios

  • Integration of EtherNet/IP devices into legacy SLC 500 systems

  • SCADA and distributed control systems requiring Ethernet communication

  • Industrial automation in food processing, petrochemical, pulp and paper, and automotive manufacturing

FAQ

  • Q: How many registers can be exchanged with the processor?  A: Up to 4000 registers.

  • Q: What controllers are supported?  A: Compatible with SLC 5/02 M0/M1 capable processors and newer.

  • Q: How many user-defined commands are supported?  A: Up to 100 commands.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more