ProSoft 5201-DFNT-MCM EtherNet/IP to Modbus Communication GatewayProSoft 5201-DFNT-MCM EtherNet/IP to Modbus Communication GatewayProSoft 5201-DFNT-MCM EtherNet/IP to Modbus Communication Gateway
ProSoft 5201-DFNT-MCM EtherNet/IP to Modbus Communication Gateway
ProSoft 5201-DFNT-MCM EtherNet/IP to Modbus Communication Gateway
ProSoft 5201-DFNT-MCM EtherNet/IP to Modbus Communication Gateway

ProSoft 5201-DFNT-MCM EtherNet/IP to Modbus Communication Gateway


Only 10 left - Selling fast

PRODUCT SKU : 5201-DFNT-MCM

PRODUCT TYPE : Communication Gateway

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 5201-DFNT-MCM communication module from ProSoft Technology is a DIN-rail mounted gateway designed to bridge EtherNet/IP networks with Modbus devices. It provides engineers with a flexible and reliable solution for integrating heterogeneous protocols in industrial automation environments.

Key Specifications

  • Manufacturer: Allen Bradley / ProSoft Technology

  • Model: 5201-DFNT-MCM

  • Product Type: EtherNet/IP to Modbus Communication Gateway

  • Mounting: DIN-rail stand-alone installation

  • EtherNet/IP Protocol Support: Explicit Messaging implementation

  • Modbus Protocol Support: Master and Slave modes supported

  • User Configuration: Operates as both Client and Server

  • Data Transfer Capacity: 125-word read and write lengths

  • Data Handling: Supports floating point data exchange

  • Server Mode: Accepts multiple client commands to read/write internal registers

  • Client Mode: Manages read/write data transfer between EtherNet/IP devices and Modbus endpoints

Core Features

  • Seamless integration between EtherNet/IP and Modbus networks

  • Flexible configuration options for client/server roles

  • Robust data handling including floating point support

  • Scalable communication for multiple devices simultaneously

Application Scenarios

  • Connecting Modbus-based sensors, drives, and controllers to EtherNet/IP PLCs

  • Industrial automation requiring interoperability between legacy Modbus devices and modern Ethernet networks

  • Distributed control systems where protocol conversion is essential

FAQ

  • Q: Can the 5201-DFNT-MCM act as both a Modbus Master and Slave?  A: Yes, it supports both roles for maximum flexibility.

  • Q: What is the maximum data transfer length supported?  A: Up to 125 words for both read and write operations.

  • Q: Does the module support floating point data?  A: Yes, it can handle floating point values for advanced applications.

Comparison with Similar Modules

  • MVI56-MCM: Focused on Modbus communication only, without EtherNet/IP support.

  • MVI56-EIP: Provides EtherNet/IP communication but lacks Modbus protocol integration.

  • 5201-DFNT-PDPS: Offers EtherNet/IP to PROFIBUS connectivity for different network requirements.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more