PRODUCT SKU : MU-FOED02 51197564-200

PRODUCT TYPE : Fiber Optic Signal Extender

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell MU-FOED02 (Part Number: 51197564-200) serves as a high-performance Fiber Optic Signal Extender designed for large-scale industrial control networks. It converts electrical signals into optical pulses to facilitate long-distance data transmission across the Universal Control Network (UCN) or Data Hiway. This module eliminates the distance limitations of copper cabling while providing total immunity to ground loops. We supply this unit as 100% Brand New Original equipment to ensure maximum network backbone stability.

Technical Specifications

The MU-FOED02 utilizes precision optics to maintain signal integrity over extended spans:

Feature Specification Details
Manufacturer Honeywell (USA)
Model Number MU-FOED02
Part Number 51197564-200
Function Fiber Optic Signal Extension / Conversion
Weight 2.86 kg (6.3 lbs)
Dimensions 25 cm x 10 cm x 8 cm
Housing Material Industrial-Grade Ruggedized Chassis
Country of Origin USA
Condition 100% Brand New Original

Engineering Advantages

  • Total EMI/RFI Immunity: By utilizing fiber optic media, the MU-FOED02 shields your control signals from electromagnetic interference. This allows for safe signal routing through high-voltage switchgear rooms and areas with heavy motor activity without data corruption.

  • Distance Extension: This module overcomes the physical limitations of standard coaxial or twinaxial cables. It enables the connection of remote I/O racks and control stations located kilometers away from the central processor.

  • Ground Loop Elimination: The optical isolation provided by the MU-FOED02 prevents electrical current from flowing between different plant grounding systems. This protects sensitive controller electronics from damage during lightning strikes or power surges.

  • Heat Dissipation Design: Despite its significant 2.86 kg mass and rugged chassis, the unit manages thermal loads efficiently within standard control cabinets, ensuring continuous 24/7 operation in demanding process environments.

FAQs

  • Does this extender require specific fiber cable types?

    The MU-FOED02 typically interfaces with standard industrial multi-mode fiber. For optimal performance and to meet Honeywell's decibel (dB) loss budget specifications, ensure your fiber terminations meet the required polish and connector standards defined in the TDC 3000 installation manual.

  • Can the MU-FOED02 replace older copper-based repeaters?

    Yes. Engineers frequently use this module to upgrade legacy copper segments to fiber optics. This transition improves network reliability and provides a more robust infrastructure for high-speed data traffic.

  • What are the primary installation requirements for this module?

    Mount the unit securely within a standard Honeywell FTA mounting channel or cabinet. Ensure the fiber optic bend radius adheres to manufacturer limits to prevent signal attenuation or physical damage to the glass core.

  • Is this unit compatible with both TDC 3000 and Experion PKS?

    Yes, this extender supports the signal translation required for various Honeywell control architectures that utilize UCN or similar high-level data links. Always verify your specific system topology before integration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more