Skip to content

What are you looking for?


You may also like

IS200SSCAH2AGD | GE Mark VI Series | Serial Communication I/O Terminal BoardIS200SSCAH2AGD | GE Mark VI Series | Serial Communication I/O Terminal BoardIS200SSCAH2AGD | GE Mark VI Series | Serial Communication I/O Terminal Board
IS200SSCAH2AGD | GE Mark VI Series | Serial Communication I/O Terminal Board
IS200SSCAH2AGD | GE Mark VI Series | Serial Communication I/O Terminal Board
IS200SSCAH2AGD | GE Mark VI Series | Serial Communication I/O Terminal Board

IS200SSCAH2AGD | GE Mark VI Series | Serial Communication I/O Terminal Board


Only 10 left - Selling fast

PRODUCT SKU : IS200SSCAH2AGD

PRODUCT TYPE : Communication I/O Terminal Board

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IS200SSCAH2AGD Serial Communication I/O Terminal Board is part of GE’s Mark VI Series, designed to provide flexible and reliable serial communication for industrial control systems. This board supports multiple signal types and offers up to six configurable channels, making it suitable for complex automation environments.

Technical Specifications

  • Model: IS200SSCAH2AGD

  • Series: GE Mark VI

  • Communication Support: RS-232C, RS-485, RS-422

  • Channels: 6 independent serial channels

  • Connection Points per Channel: 6

  • Connector Type: DC-37 pin connector (compatible with PSCA I/O pack)

  • Ethernet Interface: I/O pack to controller communication

  • Signal Layout per Channel:

    • Signal lines: A, B, C, D

    • Signal return: RET

    • Shield common: SCOM

  • Terminal Arrangement:

    • Bottom row: Channels 5, 4, 1

    • Top row: Channels 6, 3, 2

  • Termination Options:

    • Termination resistors required for RS-422/RS-485

    • Configurable via jumpers JP1A and JP1B (A-B and C-D lines)

    • Default jumper setting: disconnected

    • Clear board markings for termination setup

Application Scenarios

  • Power plant control systems

  • Industrial automation networks

  • High-reliability communication in distributed control systems

  • Integration with GE Mark VI turbine and process controllers

FAQ

Q: Can this board be used with non-GE controllers?  A: While designed for GE Mark VI systems, the board supports standard RS-232C, RS-422, and RS-485 protocols, allowing integration with compatible third-party devices.

Q: How do I configure termination resistors?  A: Use jumpers JP1A and JP1B to enable or disable termination on A-B and C-D lines. By default, jumpers are open (no termination).

Q: What is the advantage of Ethernet communication from the I/O pack?  A: It ensures fast and reliable data transfer between the I/O pack and the controller, reducing latency in industrial control applications.

Comparable Models

  • IS200PSCAH2A – Similar functionality but optimized for fewer channels.

  • IS200SSCAH1A – Earlier version with limited configuration flexibility.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more