Skip to content

What are you looking for?


You may also like

Honeywell TK-FTEB01 51309512-175 Experion PKS Fault Tolerant Ethernet ModuleHoneywell TK-FTEB01 51309512-175 Experion PKS Fault Tolerant Ethernet ModuleHoneywell TK-FTEB01 51309512-175 Experion PKS Fault Tolerant Ethernet Module
Honeywell TK-FTEB01 51309512-175 Experion PKS Fault Tolerant Ethernet Module
Honeywell TK-FTEB01 51309512-175 Experion PKS Fault Tolerant Ethernet Module
Honeywell TK-FTEB01 51309512-175 Experion PKS Fault Tolerant Ethernet Module

Honeywell TK-FTEB01 51309512-175 Experion PKS Fault Tolerant Ethernet Module


Only 10 left - Selling fast

PRODUCT SKU : TC-FTEB01 51309512-175

PRODUCT TYPE : Ethernet Communication Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The TK-FTEB01 (51309512-175) is a high-performance communication interface engineered for the Honeywell Experion PKS (Process Knowledge System) architecture. This Fault Tolerant Ethernet (FTE) bridge module is critical for establishing redundant, high-availability network connections between the controller backplane and the global user station or other FTE nodes. By utilizing dual-path communication, it ensures that process data remains accessible even in the event of a single network cable or switch failure.

Technical Specifications

  • Identification Number: TK-FTEB01

  • Associated Part Number: 51309512-175

  • Network Protocol: Fault Tolerant Ethernet (FTE)

  • Physical Interface: Dual RJ45 ports for redundant network links

  • Chassis Compatibility: Series C I/O and C300 Controller environments

  • Dimensions: 2.9 cm x 20 cm x 6.5 cm

  • Net Weight: 1.48 kg

  • Manufacturing Origin: USA

  • Environmental Rating: Industrial grade for control room cabinet installation

Application and Redundancy

The TK-FTEB01 (51309512-175) is specifically deployed in mission-critical applications where network downtime can lead to process interruption. It provides a seamless transition between Ethernet A and Ethernet B paths. When integrated with FTE switches, this module allows the system to view the redundant physical network as a single logical entity, simplifying IP management while maximizing uptime.

Frequently Asked Questions

  • Does this module support standard 10/100/1000 Mbps speeds?

    The TK-FTEB01 is optimized for industrial Ethernet speeds consistent with Series C hardware requirements, typically operating at 100 Mbps to ensure stable, deterministic communication.

  • Can it be replaced while the system is under power?

    Yes, this module supports hot-swapping within a powered rack, provided the system configuration and redundancy settings allow for a temporary single-path state during the swap.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more