Skip to content

What are you looking for?


You may also like

Honeywell TC-FCCN01 ControlNet to FLEX I/O Gateway Interface ModuleHoneywell TC-FCCN01 ControlNet to FLEX I/O Gateway Interface ModuleHoneywell TC-FCCN01 ControlNet to FLEX I/O Gateway Interface Module
Honeywell TC-FCCN01 ControlNet to FLEX I/O Gateway Interface Module
Honeywell TC-FCCN01 ControlNet to FLEX I/O Gateway Interface Module
Honeywell TC-FCCN01 ControlNet to FLEX I/O Gateway Interface Module

Honeywell TC-FCCN01 ControlNet to FLEX I/O Gateway Interface Module


Only 10 left - Selling fast

PRODUCT SKU : TC-FCCN01

PRODUCT TYPE : ControlNet Gateway Adapter

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The TC-FCCN01 acts as a high-speed communication bridge, facilitating the integration of decentralized FLEX I/O modules into a primary Honeywell ControlNet network. This non-redundant gateway adapter is engineered to translate complex control logic into field-side execution with deterministic performance. It allows for the expansion of I/O capacity without requiring additional local controllers, making it a cost-effective solution for distributed process control. The module features an integrated 3-digit LED diagnostic display, providing real-time status updates and error codes to assist maintenance personnel in rapid troubleshooting.

Technical Specifications

  • Model Identification: TC-FCCN01

  • Primary Function: ControlNet Gateway / Adapter for FLEX I/O

  • Communication Throughput: 5 Mbit/s (Standard ControlNet Speed)

  • Expansion Capacity: Support for up to 8 distributed FLEX I/O modules

  • Operating Supply Voltage: 24VDC (Nominal)

  • Diagnostic Interface: 3-digit LED status indicator

  • Installation Hardware: Compatible with 35mm DIN rail or direct panel mounting

  • Operational Temperature Range: -20°C to +80°C

  • Physical Dimensions: 87 mm x 94 mm x 69 mm

  • Net Weight: 2.72 kg (approx. 6.00 lbs)

Deployment Architecture

The TC-FCCN01 is typically installed in remote junction boxes or secondary control cabinets where field-level wiring is concentrated. By utilizing the 5 Mbit/s ControlNet protocol, this gateway ensures that digital and analog data from up to eight I/O modules is transmitted back to the central controller with minimal latency. Its broad operating temperature range (up to 80°C) allows for deployment in harsh industrial environments where standard networking hardware might fail due to thermal stress.

Frequently Asked Questions

  • Does this module support media redundancy?

    The TC-FCCN01 is a non-redundant gateway module. For applications requiring dual-cable media redundancy, a dedicated redundant-capable adapter should be utilized.

  • How are node addresses configured on this unit?

    The ControlNet node address is typically set via hardware switches on the module or through the 3-digit LED display interface, allowing for unique identification within the network segment.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more