Product Overview

The Honeywell 51400955-100 functions as a high-speed Process Network Interface (PNI) module within the Honeywell TDC 3000 Distributed Control System (DCS) topology. This communications card acts as a dedicated network bridge, routing critical real-time loop variables, alarm configurations, and peer-to-peer data packets between the processing nodes and the supervisory control network. We supply this network hardware exclusively in 100% brand new, original factory-sealed condition to eliminate packet loss, prevent communication timeouts, and guarantee deterministic data refresh rates across the plant network.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Part Number 51400955-100
Product Type Process Network Interface (PNI) Module
System Architecture Honeywell TDC 3000 DCS Network
Country of Origin United States (USA)
Physical Dimensions 12.7 cm x 12.7 cm x 12.7 cm (5.0" x 5.0" x 5.0")
Net Weight 0.8 kg (1.76 lbs)
Form Factor Configuration Compact Cube Chassis Nest Component

Engineering Advantages

  • Maximizes Slot Density with Cube Geometry: The unique 12.7 cm x 12.7 cm x 12.7 cm cube design packs multi-layered communications circuitry into a condensed, symmetric footprint. This configuration minimizes physical hardware size, allowing engineering teams to stack network interfaces inside tight, crowded marshalling panels.

  • Rejects Intense Plant-Floor EMI: Integrated high-frequency filtering networks and optical isolation channels separate the critical communication logic paths from external noise. This architecture repels electromagnetic interference (EMI) caused by nearby variable speed motor drives and high-voltage power conduits.

  • Eliminates Mechanical Contact Wear: The rigid module frame fits snugly into standard Honeywell card cage guides. This tight mechanical tolerances stop micro-vibrations from stressing the edge connector pins, preventing intermittent communication drops in high-vibration turbine or compressor environments.

  • Optimizes Passive Chassis Airflow: The exact cubical spacing creates uniform ventilation clearances around the installed module housing. This dimensional uniformity allows cabinet cooling air to pass unimpeded, preventing localized thermal buildup that degrades neighboring processing electronics.

FAQs

  • Does this network interface require field-flashing of the network address prior to installation?

    The 51400955-100 module features an onboard hardware-detectable ID. However, you must verify and set any physical address dip-switches or jumper pins on the backplane or module frame to match your system’s specific node map before plugging the card into an active rack.

  • Is this product a pulled surplus part or an official factory-fresh component?

    We guarantee this item arrives in 100% brand new, authentic, completely unused original factory condition. It ships in original manufacturer protective anti-static packaging, complete with intact factory quality-assurance tracking barcodes and serialization labels.

  • What insertion techniques protect the 51400955-100 from damage?

    Isolate power to the target chassis slot area before introducing the hardware. Wear a verified, grounded electrostatic discharge (ESD) wrist strap, align the module’s mounting sliders with the plastic chassis guides, and slide the module smoothly inward until the multi-pin backplane seating tabs snap firmly into place.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more