Skip to content

What are you looking for?


You may also like

GE Multilin UR-9VM UR9VM CPU Communications Module (RS485 + Ethernet)GE Multilin UR-9VM UR9VM CPU Communications Module (RS485 + Ethernet)GE Multilin UR-9VM UR9VM CPU Communications Module (RS485 + Ethernet)
GE Multilin UR-9VM UR9VM CPU Communications Module (RS485 + Ethernet)
GE Multilin UR-9VM UR9VM CPU Communications Module (RS485 + Ethernet)
GE Multilin UR-9VM UR9VM CPU Communications Module (RS485 + Ethernet)

GE Multilin UR-9VM UR9VM CPU Communications Module (RS485 + Ethernet)


Only 10 left - Selling fast

PRODUCT SKU : UR9VM

PRODUCT TYPE : CPU Communications Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview  

The GE UR9VM CPU Module is part of the Multilin Universal Relay (UR) series. It integrates advanced communication interfaces, combining RS485 and multiple Ethernet ports, to support high-speed data exchange and relay coordination. Designed for reliability, the UR9VM ensures efficient processing and secure connectivity in industrial and utility power systems.

Technical Specifications

  • Manufacturer: General Electric (GE)

  • Model: UR9VM

  • Type: CPU Communications Module

  • Interfaces:

    • 1 × RS485 port

    • 3 × 100Base-TX Ethernet ports

  • Voltage Supply: 120/240 V AC/DC

  • Frequency: 50/60 Hz

  • Power Consumption: Approx. 15 W

  • Contact Rating: 10 A (typical)

  • Software Compatibility: EnerVista UR software suite

  • Mounting: Modular slot-based installation

  • Dimensions: Compact design for UR series integration

  • Weight: Approx. 0.3–0.5 kg

Key Features

  • Combines RS485 and Ethernet interfaces for versatile communication

  • Supports high-speed data transfer and relay coordination

  • Compact CPU design for efficient integration into UR systems

  • Compatible with EnerVista UR software for monitoring and configuration

  • Rugged construction for reliable operation in harsh environments

Applications

  • Substation automation requiring CPU and communication expansion

  • Power system monitoring and relay-based control

  • Industrial process automation with Ethernet and RS485 connectivity

  • Mission-critical environments needing secure and reliable communication

FAQ

  • Q: What communication interfaces does the UR9VM provide?  A: It includes 1 RS485 port and 3 Ethernet ports (100Base-TX).

  • Q: What software is compatible with the UR9VM?  A: It integrates with EnerVista UR software for configuration and diagnostics.

  • Q: How is the UR9VM installed?  A: It uses modular slot-based installation for easy integration into UR systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more