PRODUCT SKU : DS200LDCCH1ALA

PRODUCT TYPE : CPU Processors

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The General Electric DS200LDCCH1ALA, also cataloged as the DS200LDCCH1ALA Drive Control/LAN Communications Board, operates as a dedicated hardware component for multi-processor I/O coordination and network data exchange within Mark V drive control system platforms.

Hardware Specifications

Parameter Specification
Model DS200LDCCH1ALA
Brand General Electric
Processor Architecture 4 (DCP, LCP, MCP, CMP)
Interface Support DLAN+, Genius, CPL, C-Bus

Industrial Control and Drive Systems

The DS200LDCCH1ALA utilizes backplane bus communication velocity to synchronize multi-processor I/O operations. The module facilitates I/O density scaling by employing four dedicated microprocessors: the DCP for analog/digital filtering, the LCP for network traffic management, and the MCP/CMP pair for motor control computations. Firmware flash compatibility supports logic-level adjustments for various protocols, including DLAN+ and Genius interfaces. Integration into DIRECTO-MATIC 2000 systems requires adherence to deterministic network timing; external terminal boards, such as the DS200ADCI, are required for CPL and C-Bus differential signaling to maintain bus integrity.

Frequently Asked Questions (FAQ)

Q: Are additional hardware modules required for specific bus system compatibility?

A: Yes. When interfacing with Genius, CPL, or C-Bus protocols, an optional DS200ADCI terminal board is required to support the specific physical layer requirements of these differential bus systems.

Q: What is the function of the onboard RESET button?

A: The physical RESET button is provided to clear operational faults and force a processor re-initialization sequence, which is used to recover the module from specific logic hang conditions without a full power cycle.

Field Installation Guidelines

  • Processor Initialization: Upon system activation, verify the DCP and LCP status indicators. If the LCP fails to filter LAN signals, inspect the communication cabling and ensure correct protocol settings via the firmware configuration.
  • Component Handling: The PCB is treated with conformal coating. Do not apply solvents to the surface during cleaning, as this may degrade the protective layer. Use only ESD-safe brushes for particulate removal.
  • Bus Termination: When utilizing C-Bus or CPL interfaces, verify that the differential bus is properly terminated at the end-of-line nodes to prevent signal reflections that can corrupt digital communication.
  • Keypad Interface: The attachable alphanumeric keypad must be seated firmly onto the board header. Ensure the ribbon cable is routed to prevent strain on the connector pins, as intermittent connections will result in input errors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more