Product Details

Product Overview

The Allen Bradley 1203-GK1 serves as a high-speed communication gateway that bridges SCANport-based devices—primarily PowerFlex and 1336 PLUS drives—to an Allen Bradley Universal Remote I/O (RIO) network. This module enables a PLC-5, SLC 500, or ControlLogix processor to control, configure, and monitor drive parameters over long distances using standard RIO protocols. We supply this unit as 100% Brand New and Factory Original, ensuring immediate network compatibility and long-term signal integrity for your legacy automation infrastructure.

Technical Specifications

The 1203-GK1 hardware utilizes a dedicated 8-pin mini-DIN interface and high-speed differential signaling to manage data exchange:

Feature Specification
Network Interface Universal Remote I/O (RIO)
Device Interface SCANport (8-pin mini-DIN)
Supply Voltage 24V DC ±10%
Supported Baud Rates 57.6K, 115.2K, 230.4K Baud
I/O Data Capacity Up to 8 I/O Words
Rack Addressing 1/4, 1/2, 3/4, or Full Rack
SCANport Load 60 mA DC
Mounting 35mm DIN Rail
Enclosure Rating IP30 (NEMA 1)
Operating Temp 0°C to +50°C (32°F to 122°F)

Engineering Advantages

  • Seamless Legacy Drive Integration: The 1203-GK1 allows modern control systems to access legacy drive data without replacing the motor control hardware. It translates complex drive parameters into standard I/O words, simplifying the integration of 1336 PLUS or PowerFlex 70 drives into existing RIO scanners.

  • Flexible Addressing Logic: Onboard DIP switches allow engineers to set rack addresses and baud rates manually. This hardware-level configuration ensures the module retains its identity during power cycles and eliminates the need for specialized software during initial commissioning.

  • Industrial-Grade Noise Immunity: The module features an isolated 3-pin Remote I/O port. This design rejects electromagnetic interference (EMI) common in drive cabinets, maintaining 230.4K baud communication stability even in proximity to high-frequency switching noise.

  • Compact DIN-Rail Footprint: The slim IP30 housing snaps directly onto standard 35mm DIN rails. This small form factor permits installation in crowded control panels where space is at a premium, requiring only minimal clearance for the 8-pin mini-DIN cable.

  • High-Speed Data Throughput: Support for 230.4K baud rates minimizes network latency. This ensures rapid response times for drive start/stop commands and real-time speed reference updates in high-performance motion applications.

FAQs

  • Is this 1203-GK1 unit 100% Brand New?

    Yes. We guarantee this product is 100% Brand New and ships in its original Allen Bradley factory packaging. It has never seen service, ensuring the internal capacitors and connectors are in pristine condition.

  • Does the 1203-GK1 require an external power supply?

    Yes. The module requires a dedicated 24V DC power source. While it connects to the SCANport, it does not draw its primary operating power from the drive; it manages its own 0.4 A maximum input current to ensure network isolation.

  • Can I use this module to connect a drive to an EtherNet/IP network?

    No. The 1203-GK1 specifically targets Universal Remote I/O (blue hose) networks. If you require EtherNet/IP connectivity for a SCANport drive, you would typically need a 1203-EN1 or a similar bridge.

  • What cable do I need for the device connection?

    The module uses an 8-pin mini-DIN SCANport cable. Always ensure the cable length stays within the maximum recommended distance for SCANport devices to prevent signal degradation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more