Product Details

The ABB CI 773F 3BDH000395R0001, also cataloged as the CI 773F Communication Interface, operates as a dedicated hardware component for PROFIBUS DP Master protocol execution within Freelance DCS and AC 700F system architectures.

Hardware Specifications

Parameter Specification
Model CI 773F (3BDH000395R0001)
Brand ABB
Origin Germany
Weight 0.096 kg
Dimensions 28 mm x 75 mm x 135 mm
Operating Temp -20 to +70 deg C
Power Consumption 1.6 W (80 mA via CPU 24 VDC terminal)
Protocol Support PROFIBUS DP Master
Transmission Rate 9.6 kbit/s to 12 Mbit/s
Physical Interface 9-pin D-Sub connector
Hot Swap Support Supported
Ingress Protection IP20

Deterministic Network Integration and I/O Density Scaling

The CI 773F module manages high-speed PROFIBUS DP Master field bus communications, interfacing directly with local backplane bus communication velocity frameworks to streamline data exchange across Profinet and EtherNet/IP deterministic networks. Optimized internal transceiver architecture permits maximum I/O density scaling across distributed remote nodes, while onboard flash memory maintains full firmware flash compatibility during online CPU parameter updates and bus cycle reconfigurations.

Frequently Asked Questions

Q: Can the CI 773F module be replaced while the system backplane remains powered?

A: Yes, the CI 773F supports hot-swap functionality, allowing removal and insertion on an energized local base unit without disturbing CPU backplane operations.

Q: How is primary operating power supplied to the CI 773F interface?

A: Operating power is drawn directly from the 24 VDC terminal of the host CPU module across the backplane, consuming a typical current of 80 mA.

Q: What physical connector standard is required for field bus wiring?

A: Field bus cabling connects through a standard 9-pin female D-Sub connector supporting RS485 differential signaling up to 12 Mbit/s.

Field Installation Guidelines

  • Isolate or verify loop insulation on field bus cables prior to mating the 9-pin D-Sub connector to prevent transceiver damage.
  • Secure the D-Sub connector retaining screws to ensure continuous ground shield continuity across the metal housing.
  • Verify proper placement of PROFIBUS DP line termination resistors at both physical ends of the RS485 segment.
  • Maintain a minimum clearance of 25 mm above and below the module enclosure to permit natural convective heat dissipation under high ambient load conditions.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more