Skip to content

What are you looking for?


You may also like

1784-U2DN | Allen-Bradley DeviceNet to USB Communication Interface Adapter1784-U2DN | Allen-Bradley DeviceNet to USB Communication Interface Adapter1784-U2DN | Allen-Bradley DeviceNet to USB Communication Interface Adapter
1784-U2DN | Allen-Bradley DeviceNet to USB Communication Interface Adapter
1784-U2DN | Allen-Bradley DeviceNet to USB Communication Interface Adapter
1784-U2DN | Allen-Bradley DeviceNet to USB Communication Interface Adapter

1784-U2DN | Allen-Bradley DeviceNet to USB Communication Interface Adapter


Only 10 left - Selling fast

PRODUCT SKU : 1784-U2DN

PRODUCT TYPE : Communication Interface Adapter

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1784-U2DN functions as a high-performance communication bridge between a computer's USB port and a DeviceNet network. This specialized interface cable enables engineers to perform programming, configuration, and diagnostics on DeviceNet-linked devices using a standard PC. It replaces the need for internal PC cards by providing a portable, "plug-and-play" connection. We supply this unit as 100% Brand New and Original, ensuring your maintenance team possesses a factory-certified tool for reliable network commissioning.

Technical Specifications

The 1784-U2DN provides a transparent link between modern computing hardware and industrial fieldbus architectures.

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Product Type: USB to DeviceNet Communication Cable

  • Part Number: 1784-U2DN

  • Data Rates: 125 kbps, 250 kbps, and 500 kbps

  • Cable Length: 0.61 meters (2.0 feet)

  • Input Voltage: 5V DC (via USB port)

  • DeviceNet Power Requirement: 24V DC at 75 mA (from DeviceNet network)

  • Power Consumption: 0.5 Watts

  • Enclosure Rating: IP20

  • Compliance Standards: C-Tick, CE, KC, UL

  • Weight: 0.31 lbs (0.14 kg)

Engineering Advantages

  • Portable Diagnostic Flexibility: The compact, lightweight design allows technicians to carry the 1784-U2DN in a standard laptop bag. This portability solves the common industrial challenge of accessing remote DeviceNet nodes in large-scale facilities where fixed workstation access remains impossible.

  • Bus-Powered Efficiency: The adapter draws its primary operating power (5V DC) directly from the host computer's USB port. This design simplifies field use by eliminating the need for external AC power bricks or specialized batteries.

  • Auto-Baud Rate Detection: The hardware supports all standard DeviceNet transmission speeds (125/250/500 kbps). It synchronizes with the network speed automatically, reducing configuration errors during high-pressure troubleshooting sessions.

  • Integrated Network Protection: The 1784-U2DN includes built-in isolation to protect the host PC from voltage spikes or ground loops present on the industrial network. This safeguard prevents expensive hardware damage to laptops during direct field connections.

  • Universal Software Compatibility: This cable interfaces seamlessly with Rockwell Automation software suites, including RSLinx Classic. Once connected, the PC recognizes the device as a standard communication driver, allowing immediate access to RSNetWorx for DeviceNet.

FAQs

  • Does the 1784-U2DN require an external power supply?

  •  The USB side of the cable draws 5V DC from your computer. However, the DeviceNet transceiver side requires 24V DC (75 mA) from the actual DeviceNet network bus to function. Ensure your network power supply is active before attempting to browse the bus.

  • Can I use this cable with Windows 10 or Windows 11? 

  • Yes. Modern versions of RSLinx Classic (3.70 and higher) include the necessary drivers for the 1784-U2DN. Upon plugging in the USB connector, the Windows Device Manager should identify the hardware under "Universal Serial Bus controllers" or "Allen-Bradley Devices."

  • Does the 0.61-meter length limit its use in large panels? 

  • The cable length serves as a bridge to the nearest tap or port. For extended distances, you can connect the 1784-U2DN to a standard DeviceNet drop cable. Avoid using long USB extension cables, as these can degrade signal integrity and power delivery to the adapter.

  • Is this a genuine Allen-Bradley product or a generic equivalent? 

  • We guarantee this 1784-U2DN is 100% Brand New and Original. Every unit ships in factory-sealed packaging with the authentic UPC (612598524822), ensuring full compatibility with Rockwell Automation firmware and diagnostic tools.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more