PRODUCT SKU : 1783-US08T

PRODUCT TYPE : Unmanaged Ethernet Switch

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 1783-US08T (Part Number: 1783-US08T) provides a cost-effective, plug-and-play networking solution for industrial control systems. As part of the Stratix 2000 series, this unmanaged switch is designed to expand port density in small-to-medium scale automation cells without the need for complex software configuration. The rugged hardware supports copper-based Ethernet communication at speeds up to 100 Mbps, making it an ideal choice for connecting HMI terminals, PLCs, and distributed I/O modules on a local machine network.

Detailed Technical Specifications

  • Product Brand: Allen-Bradley / Rockwell Automation

  • Module Identifier: 1783-US08T

  • Network Capability: Unmanaged Layer 2 Switching

  • Total Port Count: 8 Copper Ports

  • Connector Type: RJ45 (10/100 Mbps)

  • Input Voltage Range: 18 to 30V DC or 18 to 26.4V AC

  • Nominal Supply Voltage: 24V DC / 20V AC

  • Maximum Current Draw: 400 mA

  • Peak Inrush Current: 2.2 Amps

  • Isolation Voltage: 30V (continuous), tested at 500V AC for 60 seconds

  • Power Dissipation: 4.0 Watts

  • Network Cable Requirement: Category 5e (Cat5e) or better, 2 or 4 pair

  • Mounting Configuration: 35mm DIN Rail Mount

  • Enclosure Rating: IP20 Open-style

  • Operating Temperature: 0 to 60 Celsius (32 to 140 Fahrenheit)

  • Standards Compliance: cULus Listed, CE Marked, Ex (Hazardous Locations)

Network Integration and Usage FAQ

What are the primary benefits of using an unmanaged switch like the 1783-US08T?The 1783-US08T (Catalog Number: 1783-US08T) requires zero configuration. It is designed for "broadcast" style communications where advanced features like VLANs or IGMP snooping are not required. This reduces commissioning time and eliminates the risk of accidental firmware or software misconfiguration in simple machine networks.

Does this switch support Power over Ethernet (PoE)?No, the Stratix 2000 1783-US08T is a standard data switch. It does not provide power to connected devices. If your application requires powering cameras or wireless access points through the Ethernet cable, a PoE-enabled switch from the Stratix 5700 or higher series would be necessary.

How does the 1783-US08T handle different communication speeds?Each of the 8 RJ45 ports features auto-negotiation and auto-MDI/MDIX crossover. This means the switch automatically detects the speed (10 or 100 Mbps) and duplex mode of the connected device, as well as correcting for straight-through or crossover cabling automatically.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Wellhead Control Panel (WHCP) Architecture in Oil and Gas Automation

Wellhead Control Panel (WHCP) Architecture in Oil and Gas Automation

Upstream oil and gas operations rely on specialized field control platforms to manage wellhead extraction safety and hydraulic actuation. A Wellhead Control Panel (WHCP) serves as a dedicated hydraulic and pneumatic power unit designed to operate critical Christmas Tree isolation valves. By interfacing field safety components directly with Programmable Logic Controller (PLC) architecture, a WHCP protects upstream extraction assets against overpressure, catastrophic leaks, and thermal emergencies.

Read more
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.