PRODUCT SKU : 10004/1/1

PRODUCT TYPE : FSC Communication Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Honeywell 10004/1/1 FSC Communication Module is engineered for Honeywell Fail Safe Controller (FSC) systems, providing secure and redundant communication channels between safety controllers and distributed control systems. Designed for high availability, it ensures robust data exchange in mission-critical industrial environments where reliability and safety are paramount.

Key Features

  • Manufacturer: Honeywell

  • Model Number: 10004/1/1

  • Type: FSC Communication Module

  • System Compatibility: Honeywell FSC safety systems

  • Communication Interfaces: Redundant Ethernet, RS-485, and system bus connections

  • Protocols Supported: Modbus TCP/RTU, OPC, proprietary Honeywell safety communication

  • Operating Temperature: 0 °C to 60 °C (32 °F to 140 °F)

  • Dimensions: Standard FSC rack size (approx. 3U height)

  • Weight: 1.2 kg

  • Warranty: 12 months

Application Scenarios

  • Safety-Critical Systems: Provides reliable communication for FSC controllers in petrochemical, energy, and manufacturing plants

  • Redundant Architectures: Ensures high availability with dual communication paths

  • Industrial Connectivity: Supports multiple protocols for integration with diverse devices and systems

  • Rack Integration: Standard FSC rack size for seamless installation

FAQ

Q: Which communication protocols are supported?  A: Modbus TCP/RTU, OPC, and proprietary Honeywell safety communication protocols.

Q: Does the 10004/1/1 support redundancy?  A: Yes, redundant Ethernet and RS-485 connections are supported for high availability.

Q: What is the operating temperature range?  A: The module operates between 0 °C and 60 °C.

Q: How does it compare to the Honeywell 10004/H/F module?  A: The 10004/1/1 emphasizes redundant Ethernet and system bus connections, while the 10004/H/F focuses on Modbus and Ethernet/IP integration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more