Configured for serial program downloading in Advant Master architectures, the ABB TK527V030 3BSC950004R1 (TK527V030 Interface Cable) provides direct physical/electrical execution. The prefabricated assembly establishes a point-to-point physical connection between an external PC configuration node and localized fieldbus communication modules.

Hardware Specifications

Parameter Specification
Model TK527V030
Part Number 3BSC950004R1
Brand ABB
Origin Sweden
Weight 0.295 kg net
Dimensions 3000 mm x 6.5 mm x 6.5 mm
Cable Length 3 m
Connector Configuration DE9 pin to DE9 socket (DB9 Male to DB9 Female)
Target Hardware Interfaces CI801, CI810, CI820, CI830
Operating Temp Standard industrial operating range
Power Consumption Passive physical conductor assembly (Zero draw)
Environmental Compliance Exempt from RoHS 2011/65/EU scope per Article 2(4)
Product Type Prefabricated Cable

Industrial Control and Network Determinism

The TK527V030 acts as a dedicated physical bridge to update system parameters without degrading active backplane bus communication velocity parameters. The core pinout configuration matches the voltage signaling demands required during software flash compatibility updates. When mapped alongside Profinet / EtherNet/IP deterministic networks, this cable delivers direct serial payload delivery to the target communication interfaces, eliminating signal reflection and ensuring data block integrity remains within standardized timing tolerances during local engineering firmware modifications.

Frequently Asked Questions

Q: Are additional hardware components required when using the TK527V030 to interface with a CI801 module?

A: Yes. Software downloads directly targeting the CI801 fieldbus communication module require the use of an auxiliary TK212A adapter assembly in addition to the base TK527V030 line.

Q: Can this cable be hot-plugged while the master control system is online and executing cyclic tasks?

A: Yes. Because the TK527V030 is a passive cable assembly, connecting the DE9 interfaces does not cause configuration dropouts on adjacent active slots, provided the configuration software on the PC is executed in standard download mode.

Field Installation Guidelines

  • Connector Pin Orientation: Align the DE9 pins and sockets exactly before pushing the plug assemblies together to prevent the distortion or breaking of internal physical conductors.
  • Mechanical Screw Retention: Secure both integrated thumb fasteners on the DE9 connector shells to prevent signal loss caused by localized plant vibration or stress on the 3 m cable run.
  • Separation from Power Sources: Route the 3 m length clear of high-voltage AC/DC lines and motor drive paths to isolate the internal serial data wires from external electromagnetic coupling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more